The present paper deals the constant partially accelerated life test under the progressive Type-II censoring. Assuming that the lifetimes of test items follow Burr Type-XII distribution, the Bayes estimation procedure is used to obtain the Bayes estimates f or unknown distribution parameters and the acceleration factor. The symmetric and asymmetric both risk criteria are used for the estimation. The analysis of the present discussion has carried out by a real life example and a simulation study both.