整合式血液抽取及萃取晶片設計與製作

DESIGN AND FABRICATION OF AN INTEGRATED BLOOD DRAWING AND SEPARATING DEVICE

指導教授 : 簡昭珩
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


隨著現代生活品質的提升,人類在醫療方面的要求也因應提高,在抽血檢驗方面,有時我們抽血檢驗時所需要血量並不多,如一般健康檢查時,許多檢查所需的血量多為1-5cc,如ESR(紅血球沉積速率)為1cc,抽血時人所感受的痛楚感除了在針頭進入人體時,還有抽血量的多寡,當抽血量愈多人體痛楚感受會愈大,所以隨著未來生物晶片檢測的多元化,以及檢測靈敏度的提升,將不需抽取大量血液進行後續分析,尤其當檢測元件微小化後整合於單一晶片上,即所謂Lab-on-a-chip。 本研究將提出介電泳晶片整合抽血裝置,達到在血液檢驗時不需多抽取血液就可達到檢驗效果,利用PDMS易翻模與良好的生物相容性,PDMS抽血機構以PDMS薄膜受壓時所產生的回復力抽取血液,故不須外加泵浦;實驗並使用微機電技術製作介電泳晶片,目的在於萃取血液中細胞。 實驗結果證實PDMS抽血機構可確實抽取豬血液為0.39cc,整合的介電泳晶片可成功捉取血液中紅血球,達成萃取細胞之目的,利用此方式製作此抽血機構可達到抽血時不需太多血量與不須倚靠醫護人員抽血技術即可達到抽血並且做初步萃取血球之目的。

並列摘要


Recent years, more and more patients need medical treatment. The healthy examination is important for people. The blood is drawn for medical examination purposes. Sometimes the patient doesn’t need to be drawn too much blood for examination, such like the ESR (The erythrocyte sedimentation rate) would draw only 1cc. The feeling of the hurt during the blood drawing is the time of drawing. The development of microfluidic devices has become a popular research topic because of the advantages. They offer over conventional macroscale instruments including lower cost, lower sample and reagent consumption, adaptability for automation, and promise for portable point-of-care devices. With the development of the bioschips, and the increasing the sensitivity of the biosensors, it wouldn’t be drawn too much blood to analyze the result. When the biosensors are integrated in a chip, it calls Lab-on-a-chip. This research proposes an integrated blood drawing and separating device. It needn’t draw too much blood to achieve the analyzing. This research proposes a novel mechanism to draw blood without external pump or vacuum tank, the deformation of PDMS(Polydimethylsiloxane) is used to achieve the purpose. The operation process of the blood drawing device with the deflection of the PDMS membrane is to generate the deformation of the volume. The DEP chip is also fabricated, it is in order to separate the cells of the blood. For measuring the performance of the device, we also fabricate a PDMS tank as pig’s skin. The result of the pig’s blood drawn is 0.39cc, and the separating chip is also trapped the red cells of the blood. Finally, this research is demonstrated the drawing blood and separating purpose. It wouldn’t draw too much blood to analyze the result.

參考文獻


[1] K.Tsuchiya1 ,N.Nakanishi2 ,Y. Uetsuji2 and E.Nakamachi2 “Development of Blood Extraction System for Health Monitoring System” Biomedical Microdevices Volume 7, Number 4, 347-353(2005)
[2] S. Aoyagi; H. Izumi; Y. Isono; K. Makihira; M. Fukuda; “Biodegradable Polymer Needle Having a Trench for Collecting Blood by Capillary Force” Micro Electro Mechanical Systems, p450- 453 (2006)
[3] S.Khumpuang,; K.Fujioka,; S.Sugiyama,” Development of Bio-chemical Sensor System Integrated with Blood Extraction Device” Nano/Micro Engineered and Molecular Systems, p847-850(2007)
[4] S. Chakraborty1 and K. Tsuchiya2 “Development and fluidic simulation of microneedles for painless pathological interfacing with living systems.” Journal of Applied Physics .Page : 114701 - 114701-9(2008)
[5] K. Kaichiro; U.Yasutomo; T.Kazuyoshi; N.Eiji “Development of automatic blood extraction device with a micro-needle for blood-sugar level measurement” Proceedings of the SPIE, Volume 7268, pp. 726812-726812-10 (2008).

延伸閱讀