透過您的圖書館登入
IP:216.73.216.250
  • 學位論文

臨床脈診儀之研製

The Development of Clinical Pulse Diagnosis System

指導教授 : 魏清泉
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


近年來隨著科技進步和電腦的普及,使的醫療更加注重於數據的顯示。本研究以臨床中醫脈診系統之研發為方向,結合一套簡單快速的方法,利用DAQ擷取卡擷取生理信號,並融合一些訊號處理的技巧配合,進而達到中醫科學化的效果。 本論文系統主要以量測寸、關、尺三部位為主,醫生量測病患的脈波並透過螢幕即時顯示出來,方便幫病患診斷,增加脈波頻域分析、心電圖及HRV的比較,透過這些資訊化的數據作為輔助,使醫生的診斷結果更加準確。搭配資料管理系統,進而收集建立完整脈象資料,相信本研究對中醫脈診的醫療品質有很大的助益。

關鍵字

中醫脈診 脈波量測 心電圖

並列摘要


Due to the rapid progress in technology and computer popularization, the scientific data is more important in medical treatment. We developed a pulse diagnosis and information system of Chinese Medicine. Unifying a set of simple fast and methods, using DAQ Card to pick up the physiological signal, and using some signal processing skills, we then achieved the scientific effect for Chinese medicine. By detecting the pulses of Chun, Guan and Chy, the doctor can view the pulse in the screen. The system has the function of real-time displaying the pulses, ECG and Heart Rate Variability (HRV) analysis. In addition, the database can improve the clinical application. Then, the doctor can acquire and analyze the pulse signals more conveniently.

並列關鍵字

Pulse diagnosis of Chinese medicine pulse ECG HRV

參考文獻


[2] Lau GKK, Carman WF, Locarnini SA,et al. Treatment of chronic hepatitis B virus infection: An Asia pacific perspective [J].J Castroentrol Hepatol,14:3,1999.
[9] J. Pan and W.J Tompkins, “A real-time QRS detection algorithm ,”IEEE Transaction on Biomedical Engineering, No.3, 1985, pp.230-236.
[10] Task Force of the European Society of Cardiology the North American Society of Pacing and Electrophysiology, “Heart rate variability, Standards of Measurement, Physiological Interpretation,and Clinical Use” European Heart Journal, 17,1996, pp. 354-381.
[12] Y.Z.Yoon,M.H.Lee and K. S. Soh,”Pulse type classficication by varying contact pressure,” IEEE Eng. Med. Biol. Mag., Vol. 19, No.6, 2000.
[13] M.D.Driscoll, M.O.Arnold, G. E. Marchiori,L.A. Harker and M.H. Sherebrin, “Determination of appropriate recording force for non-invasive measurement of arterial pressure pulses,” Clin. Sci., Vol. 92, No.6, 1997.

延伸閱讀