Phillips and Cho [17] addressed a method for setting the optimum process mean when the quality characteristic is a beta distribution. They adopted the truncated quadratic loss function to measure the quality loss for a given truncated beta distribution. In this paper, we further propose the modified Phillips and Cho's [17] model with the linear quality loss for determining the optimum process mean. A numerical example is provided and the sensitivity analysis is conducted for illustration.