比較118位斜視病人在各種不同立體視覺測驗法中,發現Titmus stereotest敏感度最高,Frisby次之,TNO和Awaya New stereotest再次之,Synoptophore最不敏感。另外,由本研究可知道外斜視較內斜視有更好立體感,外斜視客觀角度愈大則立體感愈差,內斜視主觀角度愈大則立體感愈差。

關鍵字

無資料

並列摘要


Five stereogram tests, the Titmus, Frisby, TNO, Awaya New stereotests and Synoptophore were administered to 118 patients with strabismus. The Titmus stereotest was found to be the most sensitive one, the Frisby test was placed second, TNO and Awaya New stereotests were the third, and the Synoptophore the least sensitive one. One study disclosed that the exotropia patients had better stereopsis than the esotropia patients. The larger the objective angle of exotropia, the poorer the stereopsis; The larger subjective angle of the esotropia patients, the poorer stereopsis.