透過您的圖書館登入
IP:18.118.102.225
  • 期刊
  • OpenAccess

Spatial-temporal Variation and Local Source Identification of Air Pollutants in a Semi-urban Settlement in Nigeria Using Low-cost Sensors

摘要


Low-cost sensors were deployed at five locations in a growing, semi-urban settlement in southwest Nigeria between June 8 and July 31, 2018 to measure particulate matter (PM_(2.5) and PM_(10)), gaseous pollutants (CO, NO, NO_2, O_3 and CO_2), and meteorological variables (air temperature, relative humidity, wind speed and wind-direction). The spatial and temporal variations of measured pollutants were determined, and the probable sources of pollutants were inferred using conditional bivariate probability function (CBPF). Hourly PM_(2.5) and PM_(10) concentrations ranged from 20.7 ± 0.7 to 36.3 ± 1.6 μg m^(-3) and 47.5 ± 1.5 to 102.9 ± 5.6 μg m^(-3), respectively. Hourly gaseous pollutant concentrations ranged from 348 ± 132 to 542 ± 200 ppb CO, 21.5 ± 7.2 ppb NO_2 and 57.5 ± 11.3 to 64.4 ± 14.0 ppb O_3. Kruskal-Wallis ANOVA on ranks determined statistically significant spatial differences in the hourly-average pollutant concentrations. Diel variation analyses indicated that CO_2, PM_(2.5), and PM_(10) peaked in the early hours of most days, O_3 at noon while NO, NO_2, and CO peaked in the evening. Most pollutants were of anthropogenic origins and exhibited the highest contributions from the southwest at most sampling locations. There were strong similarities between pollutants source contribution at two of the monitoring sites that were in residential areas with a frequently used paved road. Mitigation strategies need to be established to avoid further deterioration of ambient air quality that negatively affect public health.

延伸閱讀