機房緊急應變中環境參數偵測及關機流程管理之研究

摘要


近年因應新興資訊服務的興起,各項服務多須利用伺服器提供運算、儲存等支援,人們已越來越依賴資訊系統,因此資訊系統的正常及穩定也就成為保證企業持續經營的關鍵,大量伺服器的資料中心在面對災難時,管理員往往只能擇重點設備關閉,一旦時間不及只能眼見大部分設備在開機運作的狀況承受災害。本研究提出建置一個機房環境偵測及伺服器關機流程管理系統,管理者可以依資訊安全管理的標準,定義機房內各伺服器的重要性,透過既有的設備來獲得環境參數,以極低成本即能組建一套功能完整的機房監控系統,以解決機房緊急應變人力不足的困境。

並列摘要


In recent years, the information services are more and more important. Services need to use the server to provide computing, storage and other functionalities. People are becoming increasingly dependent on information system and service it provided. So service availability of the system has become the key to continue operation. When a large number of servers are facing disaster situations such as power outage or fire, administrators may only have time to shut down some key equipment. When it is not shut down in time, they can only let most of the equipment stay on in the disaster condition. In this research, we propose a management system that has the ability to detect the environment parameters on the server farm and shutdown servers automatically in a predetermined sequence based on the environmental situation. Manager is required to first define the importance of each server according to the ISMS rules. The environmental parameters are retrieved through SNMP or other interface from the equipment. The resulting system is a server farm monitoring system which can be implemented in a very low cost. It can help the manager to manage servers in the situation of server farm emergency response.