透過您的圖書館登入
IP:18.188.149.194
  • 學位論文

開發側向流免疫分析試紙進行基質金屬蛋白酶偵測

Developing a Lateral Flow Immunoassay Test Strip for Matrix Metallopeptidase 9 Detection

指導教授 : 黃念祖

摘要


在 2010 年全球有 10.79% 的人口受牙周病的影響,也就是將近 7.5 億的人口總數,並造成約 539 億元的全球生產總值下降,造成巨大的經濟負擔。因此,為了解決牙周病衍生的各種社會問題,偵測早期牙周病並及時處理與治療,可大幅降低牙周病後期所需要的醫療開銷,降低國家在口腔疾病治療上的負擔。因此為了預防牙周病的發生,本論文開發了側向流免疫分析試紙,並以此裝置偵測牙周病的標準生物細胞因子-基質金屬蛋白酶 (Matrix metallopeptidase 9)。我們成功達成 (1) 金奈米粒子與 MMP-9 檢測抗體的鍵結;(2)MMP-9 抓捕抗體最佳化;(3) 樣本收集區過濾測試;(4)NC 薄膜 (Nitrocellulose) 進行 MMP-9 偵測和 (5) 銀離子強化等功能,以達成快速的檢測 MMP-9,並得到此裝置 MMP-9 的最低偵測極限 是 1.49 ng mL−1。在未來展望方面,我們希望此裝置能夠結合多重因子偵測並達到定點照護的概念。我們相信這個裝置將會對健康醫療,尤其在口腔照護方面,有長足的貢獻,並解決醫療資源短缺地區在牙周病偵測上的不便。

關鍵字

試紙 微流道 金屬蛋白酶

並列摘要


In 2010, 10.79% of the world’s population, about 750 million people, is affected by chronic periodontitis. Productivity loss from periodontitis alone is approximately $53.99 billion each year, causing a huge economic burden around the world. Therefore,the early prediction and treatment of periodontitis is critical in relieving the economic burden and medical expenses in low-resource settings. In this thesis, we developed a lateral flow immunoassay (LFIA) test strip for periodontitis diagnosis, and used the LFIA test strip to detect MMP-9, which is a standard biomarker for periodontitis. We achieved: (1) conjugation of MMP-9 antibody to AuNPs;(2) capture antibody optimization;(3)sample pad filtration;(4)MMP-9 detection by the 1/2 LFIA test strips and(5) sliver enhancement, and derive the limit of detection (LOD) of 1.49 ngmL−1. In the future, we hope this device can be applied in multiplex detection and achieve the concept of point-of-care (POC).We believe this development will be greatly contributed to health care and welfare,especially in dental care,and resource-limited country.

並列關鍵字

test strip microfluidic MMP-9

參考文獻


[1] Harley Tse Raphael Wong. Lateral Flow Immunoassay. Humana Press,2009.
[2] Elisângela M. Linares et al. Enhancement of the detection limit for lateral flow immunoassays: evaluation and comparison of bioconjugates. Journal of immunological methods,375(1):264–270,2012.
[3] Staffan Birnbaumetal. Latex-based thin-layer immunoaffinity chromatography for quantitation of protein analytes. Analytical biochemistry, 206(1):168–171,1992.
[4] Maria Lönnberg and Jan Carlsson. Quantitative detection in the attomole range for immunochromatographic tests by means of a flatbed scanner. Analytical biochemistry,293(2):224–231,2001.
[5] Kumi Inoue et al. A competitive immunochromatographic assay for testosterone based on electrochemical detection. Talanta,73(5):886–892,2007.

延伸閱讀