透過您的圖書館登入
IP:3.138.192.146
  • 學位論文

臨床常規應用BDProbeTEC ET系統快速診斷結核分枝桿菌感染之研究

Clinical Use of BD ProbeTec ET System for the Routine Detection of Mycobacterium tuberculosis Complex in Respiratory and Nonrespiratory Specimens

指導教授 : 周希諴

摘要


研究目的 : 本研究目的在臨床常規應用BDProbeTEC ET系統(Becton Dickinson, Sparks, Md.)做為快速分子診斷方法,來鑑定肺部及肺外部檢體的結核分枝桿菌感染。 研究方法及設計 : 本研究從2002年8月到2005年3月,在中山醫學大學附設醫院,總共從248位臨床疑似結核病之病患,收集的380個肺部及肺部外檢體做分析。比較快速分子診斷方法、傳統的抗酸性染色法與結核分枝桿菌培養之敏感性、特異性、陽性預測值及陰性預測值。 結果 : 所收集的380個肺部及肺部外檢體中,有278個檢體做快速分子診斷方法,其中快速分子診斷方法從54個培養為結核分枝桿菌檢體中偵測37個檢體為陽性,陽性率為68.5%,從224個培養為陰性檢體中偵測到60個檢體為陽性,偽陽性率為26.8%。以抗酸性染色法偵測,發現陽性率為40.5%(32/72),偽陽性率為14.3%(43/301)。若以培養結核分枝桿菌陽性為”金字標準”做比較,快速分子診斷方法之敏感性、特異性、陽性預測值及陰性預測值分別為68.5%、73.2%、38.1%、及90.6%。若以痰液檢體做分析快速分子診斷方法之敏感性為68.5%,比抗酸性染色法敏感性40.5%高(p值<0.05)。在144個肺部外檢體中做快速分子診斷方法,其中快速分子診斷方法從7個培養為結核分枝桿菌檢體中偵測5個檢體為陽性,陽性率為71.4%,從137個培養為陰性檢體中偵測到28個檢體為陽性,偽陽性率為20.4%,若以培養結核分枝桿菌陽性為”金字標準”做比較,快速分子診斷方法之敏感性、特異性、陽性預測值及陰性預測值分別為71.4%、79.6%、15.2%、及98.2%。以快速分子診斷方法檢測非呼吸道檢體的敏感性低,其敏感性在肋膜液、腦脊髓液及早晨尿液檢體的分別為60%,100%和100%。在於此研究中抗酸性染色法陽性的檢體,快速分子診斷方法的敏感性是高的,81.8%於單一痰液檢體,100%於支氣管肺泡沖洗術所得的檢體,對抗酸性染色法陰性測試的敏感性是低的,66.7%於單一痰液檢體,45.5%於支氣管肺泡沖洗術所得的檢體。 結論 : 從研究結果發現快速分子診斷方法為快速及有用診斷方法、但對於抗酸性染色法陰性檢體做比較、快速分子診斷方法之敏感性仍然太低、所以快速分子診斷方法仍然不足以單用來診斷結核病。對於抗酸性染色法抹片陰性之病患,必須配合流行病之資料、病患之臨床表現、影像學變化及培養做為診斷結核病之條件。

並列摘要


Study objectives: To determine the usefulness of the BDProbeTEC ET (Becton Dickinson) Mycobacterium tuberculosis (M. tuberculosis) complex direct detection assay (DTB), acid-fast bacillus (AFB) staining, and culture for the routine detection of M. tuberculosis in respiratory and nonrespiratory specimens in a clinical setting. Design and setting: Prospective analysis of clinical and laboratory data in patients with suspected TB at Chung Shan Medical University Hospital (Taichung, Taiwan) from August 2000 to March 2005. A total of 380 respiratory and nonrespiratory specimens from 248 patients with suspected TB were analyzed using AFB smear, culture, and DTB. Results: DTB was performed in 278 specimens and was positive in 37 of 54 (68.5%) culture-positive and 60 of 224 (26.8%) culture-negative specimens. AFB was positive in 32 of 79 (40.5%) culture-positive and 43 of 301 (14.3%) culture-negative specimens. When compared with culture (“gold standard”), DTB sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 68.5%, 73.2%, 38.1%, and 90.6%, respectively. The sensitivity of a single DTB assay (68.5%) was better than AFB smear (40.5%) (P<0.05). Of 144 nonrespiratory specimens, DTB was positive in 5 of 7 (71.4%) culture-positive and 28 of 137 (20.4%) culture-negative specimens. Compared with culture, DTB sensitivity, specificity, PPV, and NPV in non-respiratory specimens were 71.4%, 79.6%, 15.2%, and 98.2%, respectively, although DTB sensitivity ranged from 60%-100% in different specimens. DTB sensitivity was high for smear-positive sputum (81.8%) and bronchoalveolar lavage(BAL) specimens (100%), but was low with smear-negative sputum (66.7%) and BAL (45.5%) specimens. Conclusions: DTB assay offers an alternative method for direct detection of M. tuberculosis in respiratory and nonrespiratory specimens. DTB assay alone is insufficient as a single diagnostic method for diagnosis of TB. Clinical diagnosis remains the ultimate decision in the management of TB, especially in smear-negative patients. In smear-negative patient, epidemiological data, clinical symptoms and signs, radiological manifestations, and the patient’s response to empirical treatment are the criteria for diagnosis of TB.

參考文獻


1. World Health Organization. (2005).Tuberculosis, Accessed at http://www.who.int/tb/en/ , World Health Organization, Geneva, Switzerland
2. Bureau for Chronic Disease Control. Tuberculosis annual report (Taiwan) 2001. Bureau for Chronic Disease Control, Taipei, Taiwan. 2002.
3. Iseman MD: A Clinician’s Guild to Tuberculosis. Philadelphia: Lippincott Williams & Wilkins, 2000; 26-39.
4. Piersimoni C, Scarparo C, Piccoli P, et al. A. Performance assessment of two commercial amplification assays for direct detection of Mycobacterium tuberculosis complex from respiratory and extrapulmonary specimens. J Clin Microbiol 2002; 40:4138-42.
5. Bergmann, JS, Keating WE, Woods GL. Clinical evaluation of the BDProbeTec ET system for rapid detection of Mycobacterium tuberculosis. J Clin Microbiol 2000; 38:863-5.

延伸閱讀