應用於近紅外光低崩潰電壓之單光子崩潰二極體偵測器

The design of a SPAD photodetector applicable in near infrared rays with low breakdown voltage

指導教授 : 徐永珍
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


近年來因為影像技術的提升,有高偵測率的光感測器十分受歡迎,但擁有操作電壓小、耗能小以及易於與外部電路整合成單一晶片等優點的單光子偵測器並沒有如預期的受到熱烈關注,其主要的因素在於單光子感測器產生的雜訊過大,但其優秀的感測能力又是我們所需求的,所以能解決其雜訊問題,對於單光子感測器的應用有著十分大的提升。 本篇論文分為兩個部分,第一部分是設計應用於近紅外光且操作接近10伏特的低崩潰電壓的單光子崩潰二極體,使用接面較深、濃度較濃的P-well對上Deep N-well接面當做PN Junction接面,經過量測結果可得到崩潰電壓為11.8-11.9伏特,而光響應度最大值落在光波長為830nm的紅外光,量測結果合乎我們所預期。 第二部分則是單光子崩潰二極體偵測器的應用,需要一個quenching circuit將崩潰的元件的操作電壓回復到初始值,並藉由調整電路中的電阻跟電容嘗試將單光子二極體的雜訊降低,而經過量測,電路可以成功與單光子崩潰二極體整合並運作,但電路考量不周,導致無法真正達到降低after pulsing雜訊的效果。

並列摘要


Along with the improvement of imaging technology, photodetectors with high sensitivity became popular. However, Single Photon Avalanche diode(SPAD), which has so many advantages such as high sensitivity and being easy to be integrated with quenching circuit, was not paid close attention by people. The reason is the noise made by SPAD. But its excellent sensing capability is what we need. If we can solve the problems of noise, it will be a big improvement for the application of SPAD. This work, contains two parts. The first part is the design of a SPAD applicable in near infrared rays with low breakdown voltage about 10 volts. We used the junction between P-well and Deep N-well, because the concentration of P-well is higher and the junction depth is deep. The measured results show that the breakdown voltage of the SPAD is about 11.8-11.9 volts and the peak of responsivity is located 830nm wavelength. The results are matched with what we expected. The second part of the thesis is the application of the SPAD photodetector. We designed a quenching circuit to recover the operating voltage to breakdown voltage. Furthermore, by adjusting the resistance and capacitance in the quenching circuit we can reduce the noise in SPAD photodetector. The measured results show that the SPAD can be integrated with the quenching circuit and is functional. However, because of some improper design in the circuit, the quenching circuit was not able to reduce the after pulsing noise.

並列關鍵字

無資料

參考文獻


[1] 戴嘉邑,標準CMOS製程之單光子偵測器,碩士論文,交通大學,新竹,2010
[2] 許方則,標準CMOS製程之低暗記數單光子崩潰二極體,碩士論文,交通大學,新竹,2012
[3] H.T.Yen, “ InGaAs Avalanche Photodiode for Single-Photon-Detector Application, ” Master thesis, National Chaio Tung University, Taiwan (2007)
[4] G. F. Dalla Betta, Advances in photodiodes : InTech, (2011).
[5] A. Gallivanovi, I. Rench and M. Ghioni, Progress in quenching circuits for single photon avalanche diodes, IEEE transactions on nuclear science, Vol .57, pp. 3815 – 3826, 2010

延伸閱讀