This investigated study the design parameters of recess, displacement and restrictor in closed-planar-type hydrostatic bearing with single-action membrane restrictions. For different displacement to calculate the load capacity, static stiffness and flow rate. Result shows that compensation design of membrane parameters can achieve the maximum static stiffness and optimal engineering design parameters.