箱型冷氣機之節能研究

The Energy-Saving Study of Packaged Air-Conditioner

指導教授 : 莫懷恩
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


臺灣在2014年空調機銷售量已達1,353,616台,如何運用節能設計以提昇空調設備之EER (Energy efficiency ratio)值,為節能之重要課題。 本研究旨在提昇R22箱型冷氣機之性能,其方法為利用箱型冷氣機運轉時所產生之大量冷凝水,並以冷凝水進入壓縮機降溫器,藉以帶走壓縮熱,降低其產生熵,達到減少壓縮功、提昇系統性能與水資源的利用。 利用熱力學第一定律分析比較改良壓縮機前後,結果顯示,壓縮機降溫器可減少25%之壓縮機產生熵,並提昇10%之COP (Coefficient of performance)值,於壓縮機消耗功率上降低80 W。

關鍵字

箱型冷氣機 節能 EER COP R22

並列摘要


The number of air-conditioning equipments sold during 2014 in Taiwan is 1,353,616. How to increase EER(Energy Efficiency Ratio) for air-conditioning equipments have become an important issue for saving energy nowadays. This study aims to improve the performance of a R22 boxed air-conditioner, by leading condensed water produced during operation of the air-conditioner into the cooler of the compressor, it brings away compressor heat , decreases entropy production, which leads to compression work decrement, system efficiency increment, and makes better use of water resources. Comparing the compressor before and after improvement by the first law of Thermodynamics, result shows that using compressor cooler reduces 25% of compressor entropy production, raises the COP by 10%, and decreases 80 watts of compressor power consumption.

參考文獻


[1] 曾君儒整理,“全國能源會議現場直擊”,能源報導,第3 頁,2015年3月.
[2] 行政院公共工程委員會,能源產業技術白皮書,經濟部能源局
,2014年5月。
[3] 行政院公共工程委員會,能源產業技術白皮書,經濟部能源局
,2012年5月。