作者(中文):張柏翔
作者(外文):Chang, Po-Hsiang
論文名稱(中文):仿生光學流體微系統晶片及其在生醫微檢測之應用
論文名稱(外文):An Optofluidic Lab-on-a-Chip Using Bionic Technologies and Its Application in Biomedical Microinstrumentation
指導教授(中文):洪健中
指導教授(外文):Hong, Chien-Chong
學位類別:碩士
校院名稱:國立清華大學
系所名稱:動力機械工程學系
學號:9633547
出版年(民國):99
畢業學年度:98
語文別:中文
論文頁數:119
中文關鍵詞:微流體系統分子拓印生物感測器
外文關鍵詞:Microfluidic systemMolecularly imprintingBiosensor
相關次數:
  • 推薦推薦:0
  • 點閱點閱:271
  • 評分評分:*****
  • 下載下載:22
  • 收藏收藏:0
[1] L. C. Clark and C. Lyons, “Electrode system for continuous monitoring in cardiovascular surgery”, Annals of the New York Academy of Sciences, Vol. 102, pp.29-45, 1962.
[2] A. J. Cunningham, Introduction to Bioanalytical Sensors. 1st ed., New York, John Wiley & Sons, 1998.
[3] P. Bergveld, “Development of an ion-sensitive solid-state device for neurophysiological measurements”, IEEE Transactions on Biomedical Engineering, Vol. 17, pp.70-71, 1970.
[4] G. G. Guilbault, “Determination of Formaldehyde with an Enzyme-Coated Piezoelectric Crystal Detector”, Analytical Chemistry, Vol. 55, pp.1682-1684, 1983.
[5] K. Reimhult, K. Yoshimatsu, K. Risveden, S. Chen, L. Yeb and A. Krozera, “Characterization of QCM sensor surfaces coated with molecularly imprinted nanoparticles”, Biosensors and Bioelectronics, Vol.23, pp.1908-1914, 2008.
[6] X. F. Wang, B. Ding, J. Y. Yu, M. Wang and F. K. Pan, “A highly sensitive humidity sensor based on a nanofibrous membrane coated quartz crystal microbalance”, Nanotechnology, Vol. 21, 2010.
[7] R. T. Krivacic, A. Ladanyi, D. N. Curry, H. B. Hsieh, P. Kuhn, D. E. Bergsrud, J. F. Kepros, T. Barbera, M. Y. Ho, L. B. Chen, R. A. Lerner, and R. H. Bruce, “A rare-cell detector for cancer”, Proceeding of the National Academy of Science, Vol.101, pp.10501–10504, 2004.
[8] C. C. Kang, C. C. Chang, T. C. Chang, L. J. Liao, P. J. Lou, W. J. Xie and E. S. Yeung, “A handheld device for potential point-of-care screening of cancer”, Analyst, Vol. 132, pp.745–749, 2007.
[9] J. H. Kai, Z. W. Zou, J. Y. Han, S. H. Lee, B. Hong, Y. J. Ren, K. A. Kang and C. H. Ahn, “Automated fluidic system with a chaotic microfluidic reaction chamber for rapid, multi-analyte immunosensing”, The 14th International Conference on Solid-State Sensors, Actuators and Microsystems, Lyon, France, June 10-14, pp.735-738, 2007.
[10] R. J. Meagher, A. V. Hatch, R. F. Renzi and A. K. Singh,” An integrated microfluidic platform for sensitive and rapid detection of biological toxins”, Lab on a Chip, Vol. 8, pp 2046–2053, 2008
[11] R. Jindal and S. M. Cramer, “On-chip electrochromatography using sol–gel immobilized stationary phase with UV absorbance detection”, Journal of Chromatography A, Vol. 1044, pp.277–285, 2004.
[12] K. W. Ro, K. Lim, B. C. Shim and J. H. Hahn, “Integrated light collimating system for extended optical-path-length absorbance detection in microchip-based capillary electrophoresis”, Analytical Chemistry Vol. 77, pp.5160-5166, 2005.
[13] P. Caglar, S. A. Tuncel, N. Malcik, J. P. Landers and J. P. Ferrance, “A microchip sensor for calcium determination”, Analytical and Bioanalytical Chemistry. Vol. 386, pp.1303-1322, 2006.
[14] H. Y. Tan, W. K. Loke, Y. T. Tan and N. T. Nguyen, “A lab-on-a-chip for detection of nerve agent sarin in blood”, Lab on a Chip, Vol.8, pp.885–891, 2008.
[15] N. Wu, L. Feng, Y. Y. Tan and J. Hu, “An optical reflected device using a molecularly imprinted polymer film sensor”, Analytica Chimica Acta, Vol. 653, pp.103–108, 2009.
[16] S. A. Piletsky, S. Subrahmanyam and A. P. F. Turner, “Application of molecularly imprinted polymers in sensors for the environment and biotechnology”, Sensor Review, Vol. 21, pp. 292-296, 2001.
[17] L. Pauling and D. Campbell, “The manufacture of antibodies in vitro”, Journal of Experimental Medicine, Vol.76, pp.211-200, 1942.
[18] G. Wulff and A. Sarhan, “The use of polymers with enzyme-analogous structures for the resolution of racemates”, Angewandte Chemie, Vol. 11, pp.341-344, 1972.
[19] L. Andersson, G. Sellergren and K. Mosbach, “Imprinting of amino acid derivatives in macroporous polymers”, Tetrahedron Letter, Vol. 25, pp.5211-5214, 1984.
[20] K. E. Kirata, M. Bartkowski and K. Haupt, “Probing the recognition specificity of a protein molecularly imprinted polymer using force spectroscopy”, Biosensors and Bioelectronics, Vol. 24, pp. 2618-2624, 2009.
[21] 李世惠、董瑞安,分子拓印高分子感測器的製作與應用,科儀新知,第27卷,第6期,12-21頁,2006。
[22] E. L. Holthoff and F. V. Bright, “Molecularly templated materials in chemical sensing”, Analytica Chimica Acta, Vol. 594, pp.147–161, 2007.
[23] 薛敬和,高分子化學實驗法,第九版,高立圖書有限公司,1997。
[24] R. M. Rowell, Handbook of Wood Chemistry and Wood Composites. 1st ed., Madison, USA, CRC Press, 2005.
[25] 周孟寬,光聚合高分子在蛋白質分析上的應用,碩士論文,台南,國立成功大學化學系,2003。
[26] E. Hedborg, F. Winquist, I. Lundstrom, L. Andersson and K. Mosbach, “Some studies of molecularly-imprinted polymer membranes in combination with field-effect devices”, Sensors and Actuators A, Physical, Vol. 38, pp.796-799, 1972.
[27] S. A. Piletsky, E. V. Piletskaya, A. V. Elgersma, K. Yano, I. Karube, Y. P. Parhometz and A. V. El'skaya, “Atrazine sensing by molecularly imprinted membranes”, Biosensors and Bioelectronics, Vol. 10, pp.959-964, 1995.
[28] C. Malitesta, I. Losito and P. G. Zambonin, “Molecularly imprinted electrosynthesized polymers: new materials for biomimetic sensors”, Analytical Chemistry, Vol. 71, pp.1366-1370, 1999.
[29] N. T. Greene and K. D. Shimizu, "Colorimetric molecularly imprinted polymer sensor array using dye displacement", Journal of The American Chemical Society, Vol. 127, pp.5695-5700, 2005.
[30] M. Petcu, P. N. Schaare and C. J. Cook, “Propofol-imprinted membranes with potential applications in biosensors”, Analytica Chimica Acta, Vol.504, pp.73–79, 2004.
[31] M. Petcu, J. Cooney, C. Cook, D. Lauren, P. Schaare and P. Holland, “Molecular imprinting of a small substituted phenol of biological importance”, Analytica Chimica Acta, Vol. 435, pp.49–55, 2001.
[32] H. C. Huang, S. Y. Huang, C. I. Lin and Y. D. Lee, ” A multi-array sensor via the integration of acrylic molecularly imprinted photoresists and ultramicroelectrodes on a glass chip”, Analytica Chimica Acta, Vol. 582, pp.137–146, 2007.
[33] S. Guillon, R. Lemaire, A. V. Linares, K. Haupt and C. Ayela, "Single step patterning of molecularly imprinted polymers for large scale fabrication of microbiochips", Lab on a Chip, Vol. 9, pp.2987–2991, 2009.
[34] 林展生,微流體多工取樣系統於分子模版感測晶片之應用,碩士論文,台南,國立成功大學工程科學系,2004。
[35] 洪偉欽,脫氫表雄固酮分子模版的製備及吸附特性之研究,碩士論文,台南,國立成功大學化學工程學系,2005。
[36] K. Makoto, T. Toshiumi, M. Takashi and A. Hiroyuki, Molecular Imprinting from Fundamentals to Application. 1st ed., Weinheim, Germany, John Wiley & Sons, 2003.
[37] K. Farrington, E. Magner and F. Regan, “Predicting the performance of molecularly imprinted polymers: Selective extraction of caffeine by molecularly imprinted solid phase extraction”, Analytica Chimica Acta, Vol. 566, pp.60–68, 2006.
[38] T. A. Sergeyeva, O. O. Brovko, E. V. Piletska, S. A. Piletsky, L. A. Goncharova, L. V. Karabanova, L. M. Sergeyeva and A. V. El'skaya, “Porous molecularly imprinted polymer membranes and polymeric particles”, Analytica Chimica Acta, Vol. 582, pp.311-319, 2007.
[39] G. J. Guan, B. H. Liu, Z. Y. Wang and Z. P. Zhang, “Imprinting of molecular recognition sites on nanostructures and its applications in chemosensors”, Sensors, Vol. 8, pp. 8291-8320, 2008.
[40] G. Khanarian, H. Celanese, “Optical properties of cyclic olefin copolymers”, Optical Engineering, Vol. 40, pp.1024-1029, 2001.
[41] S. O. Kasap, Optoelectronics and Photonics: Principles and Practices. 1st ed., Prentice Hall, 2001.
[42] D. Svobodová, P. Křenek, M. Fraenkl and J. Gasparič, “Colour reaction of phenols with the gibbs reagent - the reaction mechanism and decomposition and stabilisation of the reagent”, Mikrochimica Acta, Vol.67, pp.251-264, 1977.
[43] H. Freundlich, Colloid and Capillary Chemistry: English translation of 3rd ed., London, Methuen & Co. Ltd, 1926.
[44] H. Schwilden, H. Stoeckel and J. Schuttler, “Closed-loop feedback control of Propofol anesthesia by quantitative EEG analysis in human”, British Journal of Anaesthesia, Vol. 62, pp.290-296, 1989.
[45] H. S. Traast and C. J. Kalkman, “Electroencephalographic characteristics of emergence from Propofol/sufentanil total intravenous anesthesia”, Anesthesia & Analgesia, Vol. 81, pp.366-371, 1995.
[46] K. Leslie, D. I. Sessler, M. Schroeder and K. Walter, “Propofol blood concentration and the bispectral index predict suppression of learning during Propofol/epidural anesthesia in volunteers”, Anesthesia & Analgesia, Vol. 81, pp.1269-1274, 1995.
[47] M. H. Sims and R. E. Moore, “Auditory evoked response in the clinically normal dog: Middle latency components”, American Journal of Veterinary Research, Vol. 45, pp.2028-2033, 1984.
[48] L. McGaμghran, L. J. Voss, R. Oliver, M. Petcu, P. Schaare, J. P. M. Barnard and J. W. Sleigh, “Rapid measurement of blood propofol levels: a proof of concept study”, Journal of Clinical Monitoring and Computing, Vol.20, pp.109–115, 2006.
[49] H. D. Gibbs, “Phenol tests III. The indophenol test”, Journal Biological Chemistry, Vol. 72, pp.649-662, 1927.
[50] D. Svobodová, P. Křenek, M. Fraenkl and J. Gasparič, “The colour reaction of phenols with the gibbs reagent - the properties of the coloured product and the optimum reaction conditions”, Mikrochimica Acta, Vol.70, pp.197-211, 1978.
[51] J. C. Dacre, “Nonspecifkity of the gibbs reaction”, Analytical Chemistry, Vol. 43, pp.589-591, 1971.
[52] G. Taguchi, S. Chowdhury and Y. Wu, Taguchi's Quality Engineering Handbook. 1st ed., John Wiley & Sons, 2004
[53] J. A. Gredell, P. A. Turnquist, M. B. MacIver and R. A. Pearce, “Determination of diffusion and partition coefficients of propofol in rat brain tissue: implications for studies of drμg action in vitro”, British Journal of Anaesthesia, Vol.93, pp.810–17, 2004.
[54] K. I. Momot, P. W. Kuchel and B. E. Chapman, ”Acquisition of pure-phase diffusion spectra using oscillating-gradient spin echo”, Journal of Magnetic Resonance, Vol. 176, pp. 151-159, 2005.
[55] http://zh.wikipedia.org/wiki/
[56] A. L. Dawidowicz, R. Kalitynski, M. Kobielski, J. Pieniadz, “Influence of propofol concentration in human plasma on free fraction of the drug”, Chemico-Biological Interactions, Vol. 159, pp.149–155, 2006.
[57] A. L. Dawidowicz, A. Fijalkowska, “Determination of propofol in blood by HPLC. Comparison of the extraction and precipitation methods”, Journal of Chromatographic Science, Vol.7, pp.377-382, 1995.
 
 
 
 
第一頁 上一頁 下一頁 最後一頁 top
* *