透過您的圖書館登入
IP:3.140.185.170
  • 期刊

台北市長期照護機構空氣中細菌之分佈與特性

Distribution and Characteristics of Airborne Bacteria in long-term Care Facilities in Taipei, Taiwan

摘要


目標:瞭解我國長期照護機構空氣中細菌菌落濃度的分佈特性,以及影響細菌暴露的環境因子。方法:針對台北市五家長期照護機構進行密集的環境採樣,測量空氣中可培養性細菌菌落濃度及室內空氣品質因子,並利用統計模式評估影響室內細菌濃度的環境因子。結果:五家機構室內總菌落濃度平均值為282-812 CFU/立方公尺,部分機構的平均濃度已超過環保署空氣品質建議值500 CFU/立方公尺。最常出現的細菌類型為球菌及桿菌;革蘭氏陰性菌的濃度皆高於陽性菌。部分機構空調及通風系統出風口菌落濃度高於室內濃度,顯示空調及通風系統為微生物污染的可能來源之一。根據多變項迴歸分析結果,採樣日期(平日、假日)、採樣時段(上、下午)、機構別、有無使用空氣清淨機、二氧化碳濃度、採樣點人數等因素和菌落濃度有顯著相關。結論:各機構由於建築特性、通風量、機構內人數、清潔方式與頻率有所差異,室內微生物濃度的分佈亦不同。若機構能有效控管環境品質,應能大幅降低疾病的發生與傳播

並列摘要


This study investigated the characteristics and determinants of airborne bacteria in long-term care facilities in Taiwan. Methods: We did intensive environmental samplings, including airborne culturable bacteria and major indoor air quality factors, in five long-term care facilities in Taipei. We used statistical models to evaluate the environmental determinants of the levels of indoor bacterial colonies. Results: The average total bacterial colony concentrations in the study facilities ranged from 282 to 812 CFU/m^3. The mean bacterial colony concentrations in several facilities exceeded 500 CFU/m^3, the maximum level recommended by the Taiwan Environmental Protection Administration. Bacilli and cocci were the dominant bacteria in the study facilities. The concentrations of Gram-negative bacterial colonies were higher than those of Gram-positive bacteria. In some study facilities, the bacterial colony levels near the diffusers of AC (air conditioner) or HVAC (heating, ventilating and air conditioning) systems were higher than indoor concentrations in general, indicating that AC and HVAC systems might be potential sources of microorganisms. According to the results of multiple regression models, sampling time, different facilities, using an air cleaner or not, carbon dioxide levels, and number of people were significantly associated with indoor bacterial concentrations. Conclusions: Building characteristics, ventilation rate, number of people, and cleaning method and frequency were essential factors influencing indoor microbial distributions in long-term care facilities. Effective environmental control can reduce disease transmission and protect the health and safety of residents and staff in long-term care facilities.

參考文獻


吳欣橋、趙馨、陳叡瑜、張振平、于台珊(2007)。台北市長期照護機構生物性環境暴露評估。勞工安全衛生研究季刊。15,138-145。
內政部統計處:統計報告,2008。http://www.moi.gov.tw/stat/year.asp。引用2009/10/14。
內政部社會司老人福利:老人安養護長期照顧機構相關統計,2007 http://sowf.moi.gov.tw/04/07/07.htm。引用2009/10/14。
Andersson, AM,Weiss, N,Rainey, F,Salkinoja-Salonen, MS(1999).Dust-borne bacteria in animal sheds, schools and children's day care centres.J Appl Microbiol.86,622-634.
Bauer, M,Mathieu, L,Deloge-Abarkan, M(2008).Legionella bacteria in shower aerosols increase the risk of Pontiac fever among older people in retirement homes.J Epidemiol Community Health.62,913-920.

被引用紀錄


莊啓佑(2014)。霧化無隔膜電解水應用於空氣中細菌抑制效率之研究〔博士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU.2014.10921
簡誌良、蘇富榮、曠永銓、徐嘉彬、楊宗儒、施志恆(2019)。微生物螢光檢測儀於醫院公共空間空氣細菌篩檢與定量分析台灣公共衛生雜誌38(1),92-101。https://doi.org/10.6288/TJPH.201902_38(1).107105
胡嘉麟(2011)。醫院空氣品質之研究〔碩士論文,中臺科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0099-1511201114142596

延伸閱讀