木材窯乾時風扇轉速對乾燥速率、乾燥品質與電力消耗之影響(二)

Effects of Fan Speed on Drying Rate, Drying Quality, and Power Consumption during Kiln Drying of Wood (2)

若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


為進一步探討風扇轉速對乾燥速率、乾燥品質與電力消耗之影響,特以3 cm之香楠為試材,就1段(1000 rpm)與3段(1000 rpm,600 rpm,300 rpn)風扇馬達轉速進行試驗。結果顯示:3段轉速對乾燥速率與乾燥品質毫無減緩與降低之影響;採行3段轉速可節省電力21%以上;此外,3段轉速對加熱系統之能源消耗,亦具有極高之節省功效。

並列摘要


The objective of this research was to make a further evaluation on the effects of fan speed on drying rate, drying quality, and electricity consumption during kiln drying of wood. 1-speed(rpm=1000) and 3-speed(green~35% M. C., rpm=1000; 35%~20% M. C., rpm=600; 20%~final percentage M. C., rpm=300)fan motors were used for this study. The test material was 3 cm×15 cm×160 cm Machilus zuihoensis. The results of this study indicate that: 1. Neither the drying rate nor drying quality were reduced or degraded by using a 3-speed fan motor system. 2. The electrical power consumption of the circulation system was reduced by more than 21% by using the 3-speed fan motor system, and the energy consumption of the heating system was also reduced a great deal by 3-speed fans.

並列關鍵字

drying-rate 3-speed fans Machilus zuihoensis