In this project, in order to carry greater bearing loads and hence offer the possibility of reduction in overall bearing size for a given application.Use brominated, anodically oxidized, and pristine p-100 carbon fiber reinforced tin-lead alloy composites were fabricated by squeeze casting. The fibers were brominated by bromine vapor for 48 hours and then desorbed at 200℃ in air for 12 hours. The anodic oxidation treatment of fibers involved electrochemical etching in a dilute sodium hydroxide electrolyte for 3 min, or immersing in nitric acid for 72 hours. Finally, we accurately reproduce the composites containing surface-treated carbon fibers had higher tensile and interlaminar shear strength than the ones containing pristine carbon fibers. The composite containing brominated carbon fibers had better tensile strength than the other two surface treatments.