Have library access?
IP:44.200.94.150

Parallel abstracts


Bioresorbable devices are particularly useful for skull bone reconstruction. Different systems are now commercially available. The aim of this trial was to compare the clinical outcomes of bone flap fixation using a new bioresorbable system (Bonamates(superscript ®)) and a traditional titanium plate/screw system. Patients diagnosed with a head injury, brain tumor, or cerebral vascular stroke and who received a craniotomy in our hospital in 2003 and 2004 were randomly allocated to 2 treatment groups for skull flap fixation (study group A: Bonamates(superscript ®): n=4; control group B: titanium plate: n=4). Treatment outcomes and complication rates were compared between these 2 groups. In total, 8 patients (study groups A and B) were followed-up for at least 6 months after surgery. All patients in the study group A whose bone flap was fixed with bioresorbable plates/screws were reviewed postoperatively. Uneventful healing occurred during the entire follow-up period for all 4 patients (100%) in group A but for only 3 of 4 patients (75%) in group B. None of the patients developed postoperative complications (i.e., infection, soft tissue dehiscence, bone flap sink, or implant-related tissue reactions). After the operation, all patients in group B had severe artifacts on the imaging study (especially the computed tomographic scan), but none was seen in group A. For patients who received radiotherapy (1 from each group), the one fixed with the titanium plate had some dosimetry considerations and complications, but the one using Bonamates(superscript ®) fixation had none. There were no significant differences between the bioresorbable device and titanium fixation with respect to fracture healing, bone flap sink, or postoperative complications. But the fusion rate appeared to be higher in the Bonamates(superscript ®) group. If patients are going to receive radiotherapy (especially brain tumor patients), the Bonamates(superscript ®) system seems to be an ideal choice for bone flap fixation.

Parallel keywords

bioresorbable bone plate skull flap fixation

Cited by


李世一(2010)。使用生物可吸收性poly-5D/95L-lactide (PLA95)聚合物骨板螺釘治療節段性下頜骨骨折〔碩士論文,中山醫學大學〕。華藝線上圖書館。https://doi.org/10.6834/CSMU.2010.00126
Lee, Y. R. (2008). 論下顎鈦金屬重建骨板之併發症與其臨床危險因子之相關性研究 [master's thesis, National Taiwan University]. Airiti Library. https://doi.org/10.6342/NTU.2008.00199
楊建中(2008)。生物可吸收性骨固定裝置應用之臨床效果評估〔碩士論文,臺北醫學大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0007-2507200815454600

Read-around