透過您的圖書館登入
IP:54.175.59.242
  • 學位論文

準相位匹配二倍頻軟質子交換鎂摻雜鈮酸鋰波導研究

Process development of soft proton-exchanged waveguides in periodically poled MgO:LiNbO3 for second harmonic generations

指導教授 : 陳彥宏
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


微型化的積體雷射元件有著非常多的應用,例如藍光雷射光源對於生 物醫療、雷射列印、光學儲存與讀取以及量測系統等有許多應用;綠光雷 射光源在資料印刷,雷射顯示器,精密加工,高解析度印刷器等等領域也有諸 多應用。 本研究選用5mol.%鎂摻雜鈮酸鋰,利用該材料本身的高非線性係數及 高抗光折變損害等優良特性製作波長轉換元件。我們在鎂掺雜鈮酸鋰中做 上軟質子交換波導並利用準相匹配技術做二倍頻,在實驗上以1550nm、 1064nm、808nm 三種波段當基頻光,並做上三種不同的準相位匹配二倍頻週 期在不同鎂掺雜鈮酸鋰軟質子交換波導中,各產生波段為775nm 的紅光、 532nm 之綠光、404nm 之藍光。 在理論模擬上,我們成功利用擴散離子交換式(ion exchange equation) 建立起軟質子交換波導的擴散模型,其擴散分布曲線與實際的量測結果有 一非常相似的分布。 在實驗的量測上,我們成功做出軟質子交換波導,並利用XRD 繞射儀 確定為單一晶相,並利用Fabry-perot 的方法量得其傳播損耗約為 1.4dB/cm。在藍光二倍頻,量得其藍光輸出約為0.2mw,其轉換效率大約 48%/W;在紅光二倍頻,量到的紅光輸出約為320nw,其轉換效率約為 0.2%/W;在綠光二倍頻,並無法找到相位匹配的溫度。 綠光二倍頻相位匹配頻寬經理論計算後,只有不到一度的範圍是找不 到相位匹配的主因。而紅光二倍頻轉換效率低落,則是因為基頻光與倍頻 光模態疊加積分過小之故。

並列摘要


Integrated miniaturized laser components has a lot of applications,such as blue laser light source for bio-medical、laser printing、optical storage and retrieval and measurement systems have many applications; green laser light source in the data Printing、laser displays、precision machining、high-resolution printing devices also has many applications。 we try to develop a fabrication method of a quasi-phase-matching (QPM) second-harmonic generator in a low-loss soft proton exchange optical-waveguide for achieving a high-efficiency laser based on a 5 mol. % MgO:LiNbO3 characterized by high optical nonlinearity and high optical damage resistance。In the experiment,light source with three different wavelength in 1550nm、1064、808nm incident three different MgO:LN SPE waveguide to generate second harmonic generation in 775nm、532nm、404nm three different light。 In the theoretical simulation,we have successfully used diffusion-type ion exchange (ion exchange equation) to establish the soft proton exchange waveguide diffusion model,the diffusion distribution curve and the actual measured results have a very similar distribution。 III In the experimental measurements,we have successfully made the soft proton exchange waveguide,using XRD diffraction identified as a single phase,and the methods used Fabry-perot to measure propagation loss is about 1.4dB/cm。In the Blue light measurement,the maximum blue light output is about 0.2mw and the conversion efficiency is about 48% / W; second harmonic in the red light, the red light measurement,the maximum red light output is about 320nw and the conversion efficiency is about 48% / W; in the green light measurement,the phase matching temperature can not be found。 SHG temperature phase-matching bandwidth in green light is too small to be found in the experiment by the theoretical calculation。The reason of the low conversion efficiency in red light generation due to the bad mode overlapping integral between the fundamental frequency and second harmonic frequency。

參考文獻


[13] Photonics Industry & Technology Development Association
[14] Photonics Industry & Technology Development Association Jan 2000
[2.2-4] “Guided-to-radiation polarization mode conversion in electro-optic PPLN APE waveguides“中央大學光電科學研究所碩士論文, 鄧聖龍, 中華民國九十七年七月
[3.1-6]余兆陞,”以鎂掺雜鈮酸鋰製作二倍頻藍光雷射波導元件之製程研究”中央大學碩士論文,DOP(2007)
[4.1-3]” Active multi-channel narrowband wavelength filters and mode converters in Ti:PPLN waveguides”中央大學光電科學研究所碩士論文, 黃俊育, 中華民國九十五年十月

被引用紀錄


謝承安(2013)。軟質子交換式MgO:LiNbO3波導作為準相位匹配二倍頻產生藍光之製程與特性探討〔碩士論文,國立中央大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0031-0605201417532773

延伸閱讀