透過您的圖書館登入
IP:13.58.82.79
  • 期刊

Determination of 5-Fluorouracil in 5-Fluorouracil Injection and Human Serum by HPLC

高效液相層析法測定注射液及血清中5-Fluorouracil

摘要


本研究開發一測定注射液及血清中5-Fluorouracil(5-FU)之高效液相層析法,層析管柱為Nova-park C18(3.9 × 150 mm, 4.6 μm),移動相為5 mmol/L磷酸二氫鉀(pH 6.0):甲醇(96:4, v/v),流速為1.0 mL/min,檢測波長為254 nm,血清經AgNO3(20%)和NaCl(20%)前處理,濃度範圍0.1-100 μg/mL(R^2 = 0.9999)時呈良好線性。5-FU注射液及血清中5-FU之最低檢出限量分別為0.10和0.85 μg/mL(S/N = 10),不同濃度的平均回收率分別為95.79 - 105.1%和90.2 - 108.8%。精密度相對標差RSD為0.4%,注射液和血清的穩定性和再現性分別小於1.3和2.1%(n = 5)。血清中之不純物不會產生干擾,以本方法測定5-FU注射液及血清中5-FU具簡單、快速、敏感且精確等優點。

關鍵字

高效液相層析 5-FU 血清 濃度

並列摘要


A high-performance liquid chromatography (HPLC) method was developed for the determination of 5-fluorouracil (5-FU) in 5-FU injection and human serum. A Nova-park C18 column (3.9 × 150 mm, 4.6 μm) and mobile phase consisting of 5 mmol/L KH2PO4 (pH 6.0) - methanol (96:4, v/v) at a flow rate of 1.0 mL/min were used for separation. The detection wavelength was set at 254 nm. The human serum was treated with AgNO3 (20%) and NaCl (20%). The method showed a good linear relationship in the range of 0.1 - 100 μg/mL (R^2 = 0.9999) with limits of quantification (LOQ) at 0.10 μg/mL and 0.85 μg/mL (S/N = 10) in 5-FU injection and human serum, respectively. The average recoveries of different concentrations in 5-FU injection and human serum were 95.79 - 105.1% and 90.2 - 108.8%, respectively. The relative standard deviation (RSD) of precision was 0.4%, and those of stability and repeatability were less than 1.3% and 2.1% (n = 5) in both samples, respectively. Impurities in the human serum did not interfere with the determination of 5-FU. The method is simple, rapid, sensitive and can accurately determine 5-FU in 5-FU injection and human serum.

參考文獻


Longleg, D. B., Harkin, D. P. and Johnstor, P. G. 2003. 5-Fluorouracil: mechanisms of action and clinical strategies. Nat. Rev. Cancer 3: 330-338.
Malet-Martino, M. and Martino, R. L. 2002. Clinical studies of three oral prodrugs of 5-fluorouracil (Capecitabine, UFT, S-1): a review. Oncologist 7: 288-323.
Anderson, L. W., Parker, R. J. and Collins, J. M. et al. 1992. Gas chromatographic-mass spectrometric method for routine monitoring of 5-fluorouracil in plasma of patients receiving low-level protracted infusions. J. Chromatogr. 581: 195-201.
Shepard, D. R., Mani, S. and Kastrissios, H. et al.2002. Estimation of the effect of food on the disposition of oral 5-fluorouracil in combination with eniluracil. Cancer Chemother. Pharmacol. 49: 398-402.
Buckpitt, A. R. and Boyd, M. R. 1980. A sensitive method for determination of 5-fluorouacil and 5-fluoro-2′-deoxyuridine in human plasma by high-pressure liquid chromatography. Anal. Biochem. 106: 432-437.

延伸閱讀