We have performed the Raman experiments on polymer-dispersed liquid crystal (PDLC) films made from E7-EPO305 mixtures cured at various temperatures. The results show that, both the low frequency field applied to the sample and the liquid crystal droplet size affect the Raman intensities significantly. A simple theory that can be used to explain these results is given.