摘要


目的:本研究探索運用無線微機電感測器,分析優秀和次優秀選手在羽球正拍切球的拍振動差異。對象:受測優秀選手目前世界排名第11名(參加2012年第三十屆夏季奧林匹克倫敦奧運會);次優秀選手目前全國排名賽乙組第三名。方法:將無線微機電感測器放在球拍上,內含有三軸加速規,取樣頻率為3333Hz,當擊正拍切球時無線擷取運動學資料,並作統計分析。結果:一、兩位選手個人在無配戴與有配戴感測器在球速方面,經比對t檢定後,無顯著差異。二、球拍加速度頻譜振動頻率次數分佈,X軸優秀選手482Hz,次優秀選手振動頻率在365和378Hz;Y軸次優秀選手振動頻率在325Hz,優秀選手不明顯;Z軸優秀選手在482Hz,次優秀選手振動頻率在325和404Hz。三、球拍振動時間經檢定後發現優秀與次優秀選手在Y軸與Z軸有顯著差異(顯著差異α為0.05)。四、在球拍加速度的時域分析,優秀選手在X和Z軸最大和最小平均值與次優秀選手有顯著差異,得知優秀選手瞬間擊球點較高、較前面,明顯小於次優秀選手。結論:一、配戴感測器不會影響選手的表現。二、在球拍加速度頻譜振動頻率次數分佈中,優秀選手的X軸與Z軸頻率全高於次優秀選手。三、在振動時間中,優秀選手明顯時間短於次優秀選手,代表優秀選手在瞬間擊球後能放鬆握把,使手臂肌肉放鬆,以較容易準備下一拍擊球。四、球拍時域資料,經F和t檢定後,發現在三軸的最大和最小 平均值有顯著差異,所以優秀選手瞬間施力較小,且能較容易精準的控球。

關鍵字

微機電 加速規 頻譜分析

並列摘要


Purpose: This research explored the use of Wireless Micro Electro Mechanical Systems (MEMS) sensors to analysis the difference of badminton forehand cut vibration. Subjects: The elite athlete is ranked number 14 in the world and the sub-elite are ranked the third of group B in this Taiwan. Methods: Underneath the racket is placed a wireless MEMS sensors which includes a tri-axis accelerometer. The sample is taken on the frequency of 3333Hz. When athletes strike forehand cut racket, sensors capture measuring point of numerical data, and statistical analysis. Results: 1. Two of the contestants not worn and wore sensors in ball speed, paired t testing, no significant differences. 2. The number racket acceleration spectrum amplitude testing, the elite athlete had higher vibration frequency than sub-elite in X and Z asix. The sub-elite got 325Hz in Y asix; however, the elite athlete had no obviously performance. 3. From the test of racket vibration time, verification revealed that the elite athlete and the sub-elite had obviously difference. 4. The analysis of racket time zone, it indicated that athletes had obviously difference during the max and min average values on X and Z axis. The elite athlete stroke with the higher hitting and the ball felt in the front area than the sub-elite. Discussions: 1. Wearing sensors would not affect the athletes' performance. 2. In the distribution rate of racket acceleration spectrum amplitude, the elite athlete had higher vibration in X and Z axis. 3. In the vibration time, it indicated that the elite athlete had shorter period than the sub-elite. The elite athlete was significantly better than sub-elite. 4. From the time zone of the racket, the max and min average in tri-axis got obviously difference paired F and t test. The elite athlete got less power in a flash hitting and got better control in striking.

參考文獻


吳鴻志、陳三寶、賴慶安()。
Ahmadi, A.,Rowlands, D. D.,James, D.A.(2006).Investigating the translational and rotational motion of the swing usingaccele rometers for athlete skill assessment.IEEE SENSORS 2006.(IEEE SENSORS 2006).:
Brody, H.,Cross, R.,Lindsey, C.(2002).The physics and technology of tennis.California, USA:Racquet Tech Publishing.
張少遜(2002)。高中羽球選手不同殺球動作之三維運動學分析(碩士論文)。國立台灣師範大學。
張博、邵年(1999)。體育運動叢書─羽毛球。國家出版社。