Transient Frequency and Intensity Sensitivities of Central Auditory Neurons Determined with Sweep Tone

並列摘要


To determine the transient frequency and intensity sensitivities of central auditory neurons, we implemented an exponential sweep tone stimulus (2 sec in period, mean sweep rate 3.3 octave/sec), intensity of which varied systematically across trials. Response of single units to the stimulus was studied at the inferior colliculus (IC) of urethane-anesthetized rats. Most IC units responded to the sweep tone by one or more transient increases in discharge rate. The area of increased discharge, or response area (RA), was delineated on the frequency-intensity plane. The tip of RA gives the hest frequency (BF) and minimum threshold (MT) of the cell. We also compared the BF and MT concurrently obtained with another method, viz., the conventional 'audio-visual' method of subjective judgment. Results showed that for the same population of cells (n=130), correlation between the two methods is better for BF (r=0.91) than for MT (r=0.78). Such discrepancy was discussed in relation to the response characteristics of these central auditory neurons.