摘要


Al_2O_3-Spinel,Al_2O_3-MgO及High-Al_2O_3諸混凝土的抗渣性,以氣體燃燒旋轉式爐渣試驗爐測試,並使用轉爐渣(CaO/SiO_2=3.8,Fe_2O_3=33.4%)。三種Al_2O_3-Spinel混凝土使用同量各含73,90及94wt%Al_2O_3富鋁尖晶石。由75wt%轉爐渣及25wt%富鋁尖晶石組成的混合粉體,升溫至1400℃或1500℃,即行爐內自然冷卻,過夜取出。XRD圖形無法鑑定這些再熔過的爐渣中仍有尖晶石存在。同一混合粉體亦用在固滴測試(Sessile Drop Test),其基材為預燒過的Al_2O_3-Spinel混凝土。實驗結果顯示混凝土的抗渣性,隨源自尖晶石MgO含量的增加而增加;尖晶石在混凝土抗渣性中之功能是尖晶石熔入滲透進去的爐渣,以阻擋爐渣繼續滲透。

並列摘要


The slag resistance of Al_2O_3-spinel, Al2_O_3-MgO and high-Al_2O_3 castables was tested using a gas-fired rotary slag test furnace and BOF slag (CaO/SiO_2 = 3.8, Fe_2O_3 = 33.4wt%). The spinels used in the test contained 73, 90 and 94 wt% Al_2O_3. The XRD patterns showed that no spinels can be identified in the mixes consisting of 75 wt% BOF slag +25wt% spinel and being fired up to 1400° or 1500°C. The same mixes were used for a sessile drop test using a prefired Al_2O_3-spinel castable as a substrate. The experimental results indicate that the penetration decreases with increasing the MgO content in spinels. The role of spinel composition in the slag resistance of Al_2O_3-spinel and Al_2O_3-MgO castables is to dissolve itself in the penetrating slag and as a result to lessen the peneatration.