摘要


中華民國醫學物理學會診斷工作群匯集相關文獻,歸納數位乳房攝影系統之物理測試彙整建議書。於本建議書中,共包含乳房攝影設備初始評估在內共十六項物理測試項目,在每一測試項目中,皆概述其測試目的、所需設備、測試概念及效能判定準則等,期除能提供執行數位乳房攝影系統品保作業之專業人員做為參考依據外,亦可提供主管機關做為規劃適用於各廠牌之數位乳房攝影系統品保作業程序之參考。

並列摘要


The purpose of this report is to review and recommend physics testing of digital mammography systems, proposed by the diagnostic task group of the Chinese Society of Medical Physics, Taipei (CSMPT). This report was integrated according to some related important references and reports. Sixteen testing items including mammography equipment evaluation (MEE) were proposed. For each item, testing purpose, required equipment, procedure and criteria were summarized. The report may serve as a reference for the staff involving in the digital mammography quality control program, as well as for the authority to implement related quality assurance standards.

參考文獻


Dance DR: Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. Phys Med Biol 1990;35:1211-9.
Dance DR, Skinner CL, Young KC, et al: Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys Med Biol 2000;45:3225-40.
Dance DR, Young KC, van Engen RE : Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols. Phys Med Biol 2009;54:4361–72.
黃怡璇、王慧娟、陳建全等:傳統暨數位乳房攝影系統之物理測試彙整建議:中華民國醫學物理學會乳房攝影工作群報告。中華放射醫誌 2008;33:153-79。[Hwang YS, Wang HC, Chen CC, et al: Review and recommendations for physics testing of conventional and digital mammography: CSMPT Mammography Task Group Report. Chin J Radiol 2008;33:153-79.]