透過您的圖書館登入
IP:216.73.216.174
  • 期刊

降低健康管理中心檢體退檢率

To Reduce The Specimen Rejection Rate in a Health Management Center

摘要


檢體採檢結果乃協助醫師快速診斷及正確治療的重要依據。2016年10-12月本中心血液檢體退檢率高達1.41%,引發專案小組改善動機,目的在降低健康管理中心血液檢體退檢率。根據現況分析主要問題為:未落實血液檢體採檢作業流程、血液檢體採檢及溶血相關認知教育訓練不足、檢體條碼標籤未全面資訊化。經文獻查證及團隊討論後,擬定解決辦法,進行教育訓練、設計血液檢體採檢相關工具、血液檢體採檢流程光碟、建立檢體標籤條碼資訊化。專案實施結果發現血液檢體退檢率由1.41%降至0.08%;血液檢體採檢正確率由73.1%提升至98.1%,顯示此專案能強化護理師執行血液檢體採檢之正確性,有效降低血液檢體退檢率,以達到安全的就醫環境。

關鍵字

檢體 退檢率 護理

並列摘要


Accurate blood test results are imperative for physicians to make timely diagnosis and treatment decisions. The blood specimen rejection rate of the studied health management center was 1.41% during the 4th quarter 2016. A project improvement team formed aiming to lower the blood specimen rejection rate. Assessment of the practice situation revealed the causes of this high rejection rate included: lack of professional knowledge, inappropriate blood withdrawal procedures, hemolysis-related problems, and lack of barcode labeling on the specimen. After literature review and team discussions, the team developed a staff training programs, a blood withdrawal checklist, a multimedia disc to standardize blood withdrawal procedures, and a specimen barcode labeling system. After the implementation of the strategies, the blood specimen rejection rate reduced from 1.41% to 0.08% and the correct blood specimen collection rate increased from 73.1% to 98.1%. The project was effective in the improvement of patient safety in the medical facility.

並列關鍵字

specimen rejection rate of specimens nursing

參考文獻


D’Angelo, R., & Mejabi, O. (2016). Getting it right for patient safety: Specimen collection process improvement from operating room to pathology. American Journal of Clinical Pathology, 146(1), 8-17. https://doi.org/10.1093/ajcp/aqw057
Dikmen, Z. G., Pinar, A., & Akbiyik, F. (2015). Specimen rejection in laboratory medicine: Necessary for patient safety? Biochemistry of Medicine, 25(3), 377-385. https://doi.org/10.11613/bm.2015.037
Lee, N. Y. (2019). Reduction of pre-analytical errors in the clinical laboratory at the University Hospital of Korea through quality improvement activities. Clinical Biochemistry, 70, 24-29. https://doi.org/10.1016/j.clinbiochem.2019.05.016
李佳芳、葉筱鳳、林琪馨(2015).降低某醫學中心外科加護病房血液檢體退件率之改善案.澄清醫護管理雜誌,11(3),54-65。
汪美玲、黃淑芬、林姿秀(2015).應用品質突破模式降低內科病房血液檢體異常退件率.長庚護理雜誌,27(3),391-401。

被引用紀錄


林佩穎、張靜年、黎慈容、林佩儀(2024)。改善內科加護病房血液檢體重送率榮總護理41(3),248-257。https://doi.org/10.6142/VGHN.202409_41(3).0006