二元超低溫冷凍系統之研究

Research of Cascade Refrigeration System

指導教授 : 鄭鴻斌
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


超低溫系統通常使用二元冷凍系統(Cascade),可降低壓縮比,由於分別兩段所使用的壓縮機體積可變小,相對其耗功變小,達到節能的效果,且可輕易達到系統之操作溫度,因此,本論文利用市售二元超低溫冷凍系統,進行硬體設計、控制策略及冷媒搭配,達到此系統設計的合宜的運轉條件。由於原系統壓縮機及控制電路故障,因此,以相近排氣量之壓縮機取代,並用傳統電路取代機板電路及填充高溫段冷媒A+B與低溫段冷媒A+B,使二元冷凍系統能夠穩定降溫且達到需求溫度,在完成研製冷凍系統後庫內溫度降溫至設定值,且系統以穩定及維持庫內溫度方式下進行測試,分別以庫內溫度-60℃、-70℃、-80℃及-80℃增加負載來測試,之後運轉穩定後取兩小時的溫度及壓力數據並繪制壓焓圖計算冷凍系統效能,結果二元冷凍系統運轉-60℃時的效能為2.31、-70℃的效能為1.07、-80℃的效能為0.84及-80℃增加負載的效能為1.78,但考慮降至-80℃增加負載的降溫過程中所需時間經計算後其效能為0.33。

並列摘要


The Cryogenic systems use cascade system, thus reducing the compression ratio. As the volume of the compressors in two stages is decreased, the wasted work is reduced relatively, so that the energy can be saved, and the system operating temperature can be reached easily. Therefore, this study used the cascade refrigeration system available on the market for hardware design, control strategy and refrigerant collocation, in order to meet the appropriate operating conditions of this system design. Due to the faults of the original system compressor and control circuit, the compressor with similar discharge capacity was used instead, and the board circuit was replaced by traditional circuit. The hot section refrigerant A+B and cold section refrigerant A+B were filled in, so that the cascade system could meet the required temperature and stability. After the refrigeration system was completed. The chamber temperature was cooled to setting value, and then tested the performance of the system under the stable and maintained chamber temperature. The load was increased at the chamber temperature of -60℃, -70℃, -80℃ and -80℃ for testing. Afterwards, the temperature and pressure data in two hours stable operation were taken and the pressure-enthalpy chart was drawn to calculate the performance of refrigeration system. The results showed that the performance of cascade system in operation at -60℃ was 2.31, the performance at -70℃ was 1.07, the performance at -80℃ was 0.84 and the performance with additional load at -80℃ was 1.78, however, considering the time required in the process of cooling to -80℃ the cascade system performance was 0.33.

並列關鍵字

Cascade System Cryogenic

參考文獻


[6]鍾震麒、楊國祥、施陽正,”二元冷凍系統應用於後補式密閉型冷凍展示櫃的節能研究”, 冷凍與空調雜誌(2003)P.103-114
[1] Jianlin Yu, Hua Zhao, Yanzhong Li, “Application of an ejector in autocascade refrigeration cycle for the performance improvement”, International journal of refrigeration 3 1 ( 2008 ) 279 – 286]
[2] Giovanni Di Nicola, Fabio Polonara, Roman Stryjek , Alessia Arteconi, “Performance of cascade cycles working with blends of CO2 D natural refrigerants “, International Journal of Refrigeration 28 (2005) 130–140
[3] Giovanni Di Nicola, Giuliano Giuliani, Fabio Polonara, Roman Stryjek, “Blends of carbon dioxide and HFCs as working fluids for the low-temperature circuit in cascade refrigerating systems “, International Journal of refrigeration 34 ( 2011) 1436-1445
[4] Souvik Bhattacharyya, S. Mukhopadhyay, A. Kumar, R.K. Khurana, J. Sarkar, “Optimization of a CO2–C3H8 cascade system for refrigerationand heating”, International Journal of Refrigeration 28 (2005) 1284–1292

被引用紀錄


謝承志(2014)。二元冷凍系統之膨脹閥性能探討〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0006-0408201413090300

延伸閱讀