摘要


在本篇研究中,我們利用了頂角為165度的軸稜鏡(Axicon lens)產生貝索光束,並結合掃頻式光學同調斷層顯微術來提升橫向解析度。根據我們實驗的結果,在景深1.29mm的範圍內我們量測到的橫向解析度光點大小為~5微米,其靈敏度約為~94dB。

並列摘要


In this study, a swept source optical coherence tomography (SS-OCT) system that profits from the enhanced lateral resolution performance of Bessel beam illumination was developed. Using an axicon lens with a top angle of 165 degree, nearly constant lateral resolution of ~ 5 micro meter over a focusing depth of at least 1.29 mm is demonstrated with an invariant sensitivity of ~ 94 dB.

參考文獻


[2] A.F. Fercher, W. Drexler, C.K. Hitzenberger, T. Lasser, “Optical coherence tomography – principles and applications”, Rep. Prog. Phys. 66, 239–303 (2003).
[3] Kye-Sung Lee et al., “Fourier domain optical coherence tomography with an 800μm diameter Axicon lens for long-depth-range probing”, SPIE 6079-84 (2006).
[4] Zhihua Ding, Hongwu Ren, Yonghua Zhao, J. Stuart Nelson, and Zhongping Chen, “High-resolution optical coherence tomography over a large depth range with an axicon lens” ,Vol. 27, No. 4, OPTICS LETTERS, February 15( 2002).
[5] R. A. Leitgeb, M. Villiger, A. H. Bachmann, L. Steinmann, and T. Lasser, “Extended focus depth for Fourier domain optical coherence microscopy”, OPTICS LETTERS, Vol. 31, No. 16, August 15(2006).
[6] Kye-Sung Lee and Jannick P. Rolland, “Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range”, OPTICS LETTERS , Vol. 33, No. 15, August 1(2008).