透過您的圖書館登入
IP:3.128.203.143
  • 學位論文

框架式面板牆之隔音性能評估與量測系統建構

Establishment of Measurement Analysis System of Light Steel Partition on Sound Insulation Performance

指導教授 : 林芳銘

摘要


本研究對室內裝修常用之隔間牆種類-框架式面板牆以CNS 15160-3方式進行測量,探討框架式面板牆隔音之改善對策,並將面板種類、面板層數、填充材之變因進行比較。經實驗證實屏東科技大學建築聲學實驗室聲壓分布均勻適合進行隔音性能試驗後,以常用之裝修材料c型鋼作為骨架,測試各種材料面板隔音性能;測試結果可發現常用之室內裝修板材隔音性能,纖維水泥板因面密度最大而隔音效果最佳,增加牆體厚度與空氣層可提升牆體中低頻的隔音性能,在框架式面板牆內放入填充材玻璃纖維棉可增加整體8~10 dB之隔音性能,而雙層面板結構則可增加6~10 dB之隔音性能,另外以雙層不同面板測試後發現其結構可改善高頻之巧合頻率效應。

並列摘要


This study investigates construction method of light steel partition on sound insulation performance .These study objects used the measurement of sound isulation in CNS 15160-3 laboratory measurements of airborn sound isulation of building elements. The results showed that into the glass fiber could improve sound isulation reduced more then 8~10dB.The fiber cement board is the best than the other of sound isulation effect. Double board structure is more then single board structure 6~10dB of sound isulation performance. However,we found the different type in double board of the specimen could improvement coincidence effect at high frequencies, the surface density is the must factor of face board of sound isulation performance.

參考文獻


陳伯勳、羅時麒 (2008) 建築分間牆隔音性能與法規應用之研究。中華民國建築學會,建築學報技術專刊66:第75~89頁。
黃覺賢 (2012) 活動隔牆隔音性能之研究。國立成功大學建築研究所論文。第2-5~2-7頁。
陳展隆 (2003) 骨架面板牆施工品質管理之研究-以醫院建築為例。國立成功大學建築研究所論文。第2-1~2-9頁。
Toshio Matsumoto , Masayuki Uchida a, Hiroyuki Sugaya ,Hideki Tachibana(2005) Development of multiple drywall with high sound insulation performance. Chiba Institute of Technology, Chiba, Japan.
A. Uris, A. Llopis, J. Llinares(1998) Effect of the rockwool bulk density on the airborne sound insulation of lightweight double walls. Universidad PoliteÂcnica de Valencia, Valencia, Spain.

被引用紀錄


林彥瑜(2017)。和平民族主義──從「終戰/敗戰紀念日」記憶探討戰後日本民族主義的內涵與轉變(1945~1972)〔碩士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU201702227
詹偉雄(2011)。八卦.現代性.台北:一個敘事取向的「小報化」研究〔碩士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU.2011.10758