In this project, a mechatronical flow field visualization tester with CCD and data acquisition system is used to investigate the effects of experimental parameters, such as angle and geometry of vortex generator and flow velocity of fluid, on the distribution of flow field and temperature of the thin circular disk. By using this tester, the relationship between various electronic components and optimum angle and position of vortex generator are obtained. The experimental results would be able to improve the performance of electroni cooling.