Experimental Analysis for Thermal Performance of a Vapor Chamber Applied to High-Performance Servers

若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

並列摘要


This article conducts experimental analysis using the window program VCTM V1.0 to investigate the thermal performance of a vapor chamber and then applies the findings to a high-performance server. The experimental method is derived from a novel formula for the effective thermal conductivity of a vapor chamber and functions to calculate its thermal performance. Results show that the maximum heat flux is over 100 W/cm^2, and the effective thermal conductivity is many times higher than the copper heat spreaders. The maximum effective thermal conductivity is 870 W/m℃ according to the novel formula, and comparing it with the experimental value, the calculating error is no more than ±3%.