近本研究主要針對溫室作業場所進行空氣中細菌與真菌之調查,以瞭解目前台灣之溫室作業場所中生物性危害之程度。研究中選取3間家溫室作業場所進行採樣分析,細菌與真菌生物氣膠分佈是利用衝擊式(impactor)生物氣膠採樣器進行採樣,採樣分為上午、中午與下午三時段進行採樣。生物氣膠採集後之真菌與細菌樣本則進一步將其純化培養,再予以分子生物鑑定方式進行菌種鑑定。研究結果發現,平均細菌生物氣膠濃度達到最高1,674±296CFU/m^3,真菌生物氣膠最高可達到6,432±981CFU/m^3。菌種鑑定結果顯示,真菌有"Trichoderma" spp.、"Penicillium" spp.、"Aspergillus" spp.、"Acremonium" spp.、"Meira" spp.。細菌則有"Bacillus" spp.、"Planobacterium" spp.、"Chryseobacterium" spp.、"Jeotgalicoccus" spp.、"Staphylococcus" spp. "Nocardiopsis" spp.、"Agromyces" spp.、"Micrococcus" spp.。

關鍵字

溫室作業環境 生物氣膠 細菌 真菌 分佈

並列摘要


This study aims to investigate the airborne microorganisms and bacteria endotoxins in the greenhouse, for understanding biological hazards in Taiwan greenhouse. Three greenhouses were selected as the testing subjects. The bacteria and fungi bioaerosol distributions were sampling by impactor bioaerosol sampler. The species of bioaerosol samples in the operating workplace were finally purified, cultured, and further identificated by molecular biology. The results showed that in the greenhouses, the highest average bacteria bioaerosol concentrations was in the range of 1674±296 CFU/m^3, and the highest average fungi bioaerosols concentration was about 6,432±981 CFU/m^3. According to the identificated of molecular biology in the greenhouses, bacteria bioaerosols were "Bacillus" spp., "Planobacterium" spp., "Chryseobacterium" spp., "Jeotgalicoccus" spp., "Staphylococcus" spp., "Nocardiopsis" spp., "Agromyces" spp., and "Micrococcus" spp.. The fungi bioaerosols were "Trichoderma" spp., "Penicillium" spp., "Aspergillus" spp., "Acremonium" spp. and "Meira" spp.

並列關鍵字

Bioaerosols Greenhouse Bacteria Fungi Distribution

參考文獻


Radon, K,Danuser, B,Iversen, M,Monso, E,Weber, C,Hartung, J,Donham, KJ,Palmgren, U,Nowak, D.(2002).Air contaminants in different European farming environments.Annals of Agricultural and Environmental Medicine.9,41-8.
Mons, E.(2004).Occupational asthma in greenhouse workers.Current opinion in pulmonary medicine.10,147-50.
Hansen, VM,Winding, A,Madsen, AM(2010).Exposure to bioaerosols during the growth season of tomatoes in an organic greenhouse using Supresivit (Trichoderma harzianum) and Mycostop (Streptomyces griseoviridis).Applied and environmental microbiology.76,5874-81.
Adhikari, A,Gupta, J,Wilkins, JR,Olds, RL,Indugula, R,Cho, KJ,Li, C,Yermakov, M.(2011).Airborne microorganisms, endotoxin, and (1→3)-β-D-glucan exposure in greenhouses and assessment of respiratory symptoms among workers.Annals of occupational hygiene.55,272-85.
Illing, HPA.(1997).Is working in greenhouses healthy? Evidence concerning the toxic risks that might affect greenhouse workers.Occupational medicine.47,281-93.

被引用紀錄


莊啓佑(2014)。霧化無隔膜電解水應用於空氣中細菌抑制效率之研究〔博士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU.2014.10921

延伸閱讀