新生兒中心導管置管及管路照護完整率改善專案

Enhancement of the Completion Rate of Central Catheter Placement and Catheter Care among Newborns

摘要


本專案為運用多元策略提昇新生兒中心導管置管及管路照護完整率之改善專案。小組於2017年9月1日至9月14日,經實地觀察及查核,發現中心導管置管完整率為62.50%、管路照護完整率為66.48%;自2018年2月1日至4月30日,運用組合式照護模式、教育訓練課程、洗手運動及提醒標語等改善措施,中心導管置管完整率由62.50%提升至93.75%,管路照護完整率由66.48%提升至97.95%。由此得知,本專案所建置的多元策略可以有效提昇中心導管置管及管路照護完整率,期盼未來將此教學課程e化,廣泛推展,以作為臨床照護之參考。

並列摘要


The aim of this project was to use multiple strategies to improve the completion rate of central catheter placement and catheter care among newborns. From September 1 to 14, 2017, the placement completion rate for central catheters was 62.50% and the central catheter care completion rate was 66.48%. From February 1 to April 30, 2018, we implemented a care bundle comprising central catheter educational and training courses and hand hygiene reminders for doctors and nurses to improve the completion rate of central catheter placement and care. The completion rate for central catheter placement was increased from 62.50% to 93.75%, and the care completion rate was increased from 66.48% to 97.95%. Based on these findings, the multiple strategies adopted in this project effectively improved the placement and care completion rate for central catheters. In the future, we will establish e-learning courses that can be used as a reference for medical staff.

參考文獻


李聰明、Ling, M. L.(2016).亞太感染管制學會(APSIC)中心導管相關血流感染(CLABSI)預防指引-2015年(上).感染控制雜誌,26(2),65-81。
林秀美、陳慧琪、鄭金玫、廖浩欽、羅櫻桃、薛雅雯、劉孝有(2012).降低加護病房中心導管相關血流感染率專案.領導護理,13(1),91-101。
林佩儀、景秀蘭、簡政怡、黃惠美(2014).提升加護病房醫護人員執行中心導管組合式介入措施之完整率.榮總護理,31(3),286-294。
盛望徽、陳宜君(2017).預防中心導管相關血流感染組合式照護.內科學誌,28(1),1-6。
劉秀美、張瑛珍、呂明蕙、廖雅芬、黃苔蓮、陳雅玲…黃筱蕓(2010).降低某新生兒加護病房早產兒低體溫率之改善方案.馬偕護理雜誌,4(1),14-23。