透過您的圖書館登入
IP:3.144.187.103
  • 學位論文

電子散熱模組動態分析與研究

Transient Thermal Performance of Electronic Cooling Module

指導教授 : 陳希立
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


近年來,電子設備元件之性能不斷提升,而其發熱功率亦隨著性能提升而逐漸增加,往往需要增加熱管或散熱鰭片的總面積和數目,導致增加品管的時間,降低生產效率。為此提供一種快速檢測的方法便是當務之急。 以系統識別搭配散熱模組進行動態分析研究。研究重點著重於(1)散熱模組的動態系統的識別。(2)提供兩種步階輸入訊號以觀察散熱模組的動態響應。(3)熱管燒乾現象的探討。(4)快速檢測方法的制定。   由識別結果得知,以成功建立散熱模組的動態模型,並提供均溫箱平台改善傳統加熱平台所產生接觸熱阻問題,透過快速檢測方法的制定可以將檢測時間縮短為30秒提升品管效率。

並列摘要


In recent years, the electronic devices and components have better performance constantly. With the increasing performance, the heat generation of the electronic devices and components also increases. It frequently needs to increase those numbers of total fin areas and heat pipes , and leads the lower efficiency of manufacture by raising quality control time. Therefore, looking for rapid quality control method plays an important role. The main purpose of the research presented is to study the dynamic behavior of the electronic cooling module by using system identify method. There are four main points in the research : (1) The dynamic system identify of the electronic cooling module. (2) Observing the dynamic response of the electronic cooling module by proving two step input single. (3) The analysis of the heat pipe under drying out situation. (4) Establish the rapid quality control method. From the system identify results, the investigation successfully establishs the dynamic model for the electronic cooling module and improves the thermal interface resistance’problem by using the constant temperature heating device. By the transient behavior test in thirty seconds , it can forecast the steady performance of the electronic cooling module for establishing rapid quality control method.

參考文獻


13. 陳聖謙, 「迴路式熱虹吸管之薄膜蒸發研究」,碩士論文,國立臺灣大學機械工程學研究所,民國九十五年六月(2006)
14. 黃秉鈞,"系統識別",2006
16. 吳俊寛, 「高性能環控箱之研發」,碩士論文,國立臺灣大學機械工程學研究所,民國九十四年六月(2005)
2. Ramaswamy, C., Joshi, Y. K. and Nakayama, W., "Thermal Performance of a Compact Two-Phase Thermosyphon: Response to Evaporator Confinement and Transient Loads," Journal of Enhanced Heat Transfer, Vol. 6, No. 2-4, pp. 279-288, 1999.
3. Ramaswamy, C., Joshi, Y. K., Nakayama, W. and Johnson, W. B., "Combined Effects of Sub-Cooling and Operating Pressure on the Performance of a Two-Chamber Thermosyphon," IEEE Transactions on Components and Packaging Technologies, Vol. 23, No. 1, Mar. 2000.

延伸閱讀