影響活性碳濾毒罐效能因子評估研究

Factors Affecting Charcoal Cartridge Performance

指導教授 : 陳志傑

摘要


無資料

關鍵字

活性碳 濾毒罐 微粒 均勻度

並列摘要


Charcoal cartridges are commonly used to protect against a wide range of organic vapors in the workplaces. The service life of charcoal cartridge has been found to be affected by many factors, including assault agent, concentration, temperature, humidity and flow rate through the cartridges. Therefore, a filter unit was normally placed in front of the cartridges to protect the charcoal from contamination. However, in the practical situation, organic vapors often accompany aerosol particles. Due to the air resistance caused by the filter media, the filter units equipped in the cartridge or canister are seldom “absolute filter”, especially for respirators designed for negative pressure mode. Therefore, principal objective of this work was to study the effect of aerosol loading on the breakthrough characteristics of charcoal cartridges, as a function of particle size. A stainless holder (diameter 71.6 mm, height 25.6 mm) will be fabricated to accommodate 35.0 g of activated charcoal made of coconut shell. The charcoal powder has the BET surface area of about 1300 m2/g. Cyclohexane will be used as the assault agent. Cyclohexane vapor concentration will be controlled at 3000 ppm by passing an air flow of 15 L/min through surface of liquid cyclohexane in a jar dipped in a water bath. A flame ionization detector will be used to monitor the organic vapor concentration. A syringe pump will be used to refill the escaped cyclohexane. The relative humidity will be controlled at 50% by using a tubing pump feeding water into a needle wrapped with a heating tape. The same can of charcoal will be regenerated in a 150 C oven to remove the absorbed cyclohexane. The pressure drop across the charcoal cartridge will be monitored by using a pressure transducer, which will be calibrated against an inclined manometer. For aerosol penetration test, a constant output aerosol generator (model 3075, TSI) will be used to generate submicrometer-sized aerosols, and an ultrasonic atomizing nozzle (model 8700, Sonotek) will be used for generating micrometer-sized aerosols. An electrospray aerosol generator will be used to generate nanometer-sized particles to study the loading effect on the breakthrough characteristics of charcoal cartridge. A scanning mobility particle sizer (for aerosols < 0.7

並列關鍵字

charcoal cartridge aerosol uniformity

參考文獻


石東生、鄭蓉瑛, “有機蒸氣濾毒罐研發與性能測試”, 行政院勞工委員會勞工安全衛生研究所,1998年。
陳春萬、陳友剛, “呼吸防護具的密合度”, 勞工安全衛生簡訊第11期,行政院勞工委員會勞工安全衛生研究所,中華民國八十四年六月。
行政院勞工委員會勞工安全衛生研究所, “防護具選用技術手冊-呼吸防護具”, 中華民國八十四年六月。
Cohen, H.J. and Garrison, R.P. “Development of a Field Method for Evaluating the Service Life of Organic Vapor Cartridges:Results of Laboratory Testing Using Carbon Tetrachloride”, Am. Ind. Hyg. Assoc. J. 50(9): 486-495, 1989.
Cohen, H.J. and Garrison, R.P. “Development of a Field Method for Evaluating the Service Life of Organic Vapor Cartridges:Results of Laboratory Testing Using Carbon Tetrachloride Part II: Humidity Effects”, Am. Ind. Hyg. Assoc. J. 51(11): 575-580, 1990.

被引用紀錄


葉超仁(2015)。勞工暴露於有機溶劑蒸氣在不同作業姿勢下濃度差異之研究〔碩士論文,中山醫學大學〕。華藝線上圖書館。https://doi.org/10.6834/CSMU.2015.00075
張倩瑜(2016)。微粒負載對熱脫附管效能影響以及前置濾材開發與評估〔碩士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU201610351
蕭美芳(2008)。顆粒床過濾與負載特性〔碩士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU.2008.02054
陳俊瑋(2011)。活性碳濾材之營養源、回潮率與含水率對細菌存活率影響探討〔碩士論文,中山醫學大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0003-3008201116082600
陳孟偉(2012)。活性碳纖維濾材過濾效能及添加營養源對細菌存活率探討〔碩士論文,中山醫學大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0003-2405201211465600

延伸閱讀