地方政府建築耗能影響因子分析研究

Analysis on Energy Comsumption Effective Factors of Local Government Building

指導教授 : 李文興
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


依過去文獻多以工程模擬方式進行用電情形分析,並未以實證分析進行研究及驗證。本研究即嘗試以台灣地區91至93年3年間25縣市政府所填報能源資料為分析樣本,利用計量經濟學軟體,在產出項為單位樓地板面積總用電度數,投入項為單位樓地板面積人員總數及大氣平均氣溫設定下,來探討影響用電的因素分析。此外,並利用資料包絡分析法,在投入項為總用電度數、照明設備及空調設備,及產出項為建築物樓地板面積、辦公室人員總數、各縣市大氣平均氣溫設定下,探討那些政府機關具有真正效率。 由研究結果得知,單位樓地板面積總用電度數與單位樓地板面積人員總數及大氣平均氣溫呈線性迴歸方程式為kWh/m2 = -144.2 + 723.4 P/m2 + 7.2 T;在整體效率值達0.9~1.0之家數共14家,佔27.4%,而效率值小於0.5之家數共6家,佔11.8%;技術效率值達0.9~1.0之家數共35家,佔68.6%,而效率值小於0.5之家數共1家,佔2.0%;規模效率效率值達0.9~1.0之家數共29家,佔56.9%,而效率值小於0.5之家數共2家,佔3.9%。

並列摘要


Most of the exist power consumption analysis is used engineering simulation method, not much practical case analysis to be researched and proved for past years. In this research I try to research and analysis the effective factors of 25 local government building energy consumption by year 2002-2004. I study the effective factor power consumption by econometrics software. Beside, I use the Data Envelopment Analysis to research which is real energy efficiency – total power consumption、lighting number、air conditioners number as inputs, building area、office number、average outdoor air temperature as outputs. As a result from the research, density of power consumption per M2、density of people per M2 and average outdoor air temperature present Line Regression equation as kWh/m2 = -144.2 + 723.4 P/m2 + 7.2 T. The Aggregate Efficiency of 14 units are up to 0.9 ~ 1.0 around 27.4%, the Aggregate efficiency of 6 units are less than 0.5 around 11.8% which have to improve by energy audit. The Technical Efficiency of 35 units are up to 0.9 ~ 1.0 around 68.6%, the Technical Efficiency of 1 units are less than 0.5 around 2.0% which have to improve by energy audit. The Scale Efficiency of 29 units are up to 0.9~1.0 around 56.9%, the Sale Efficiency of 2 units are less than 0.5 around 3.9% which have to improve by energy audit.

參考文獻


[8] 楊俊欣,辦公建築空調全年耗能電腦模擬與耗能因子解析,碩士論文,國立台北科技大學冷凍空調研究所,2002年6月。
[27] Lam, J.C. and S.C.M. Hui. 1996. “A Review of Building Energy Standards andImplications for Hong Kong.” Building Research and Information 24 (3): 131-140.
[28] Nadel, S. 1997. “The Future of standards.” Energy and Buildings 26 (1): 119-128.
[31] Analysis of energy consumption in the high schools of a province in central Italy. Energy and Buildings. 34, 1003-1016.
[33] Banker, R. D., Charnes., A., Cooper,W. W. (1984) “Some Models for Estimating Technical and Scale Inefficiences in Data Envelopment Analysis,”Management Science, Vol. 30, pp.1078-1092.

被引用紀錄


連治正(2012)。應用Ecotect於政府機關戶政事務所建築物之用電指標分析〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://doi.org/10.6841/NTUT.2012.00006
楊超朋(2007)。地方政府能源密集度評估模式之研究〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://doi.org/10.6841/NTUT.2007.00460
羅婉菱(2007)。網路數位電力監測系統之建置〔碩士論文,國立中央大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0031-0207200917343588
陳明凱(2008)。溫度上升對建築物能源效率的影響分析〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0006-1407200817461300
陳芳隆(2011)。政府單位辦公室建築物空調負載模擬分析〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0006-1107201110515800

延伸閱讀