以FRP補強結構之應用及檢測研究

A Study on application and inspection of FRP-Strengthened Structure

指導教授 : 何仲明
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


結構補強採用碳纖維貼片(FRP)是現今補強工法的新趨勢,因為碳纖維貼片具有強度高、材質輕、抗腐蝕、剪裁容易及施工簡易等特性。然而,碳纖維貼片補強後的品質,傳統上依賴人工敲擊(Tapping)法或拉拔(強度)試驗來檢核,前者操作費時且人為誤差難免。本文依據紅外線原理,因為碳纖維貼片與混凝土表面結合後,經過均勻的加熱,由於內部缺陷處,產生熱流的不均勻,而與結合良好處會有溫差的情形產生,此時溫度的差異會造成釋放紅外線量不同的情形產生。所以本文嘗試利用紅外線熱像儀檢測小區域補強後的品質,試驗結果顯示此方法可以快速找到表面黏合不良的位置。 此外,目前碳纖維研究多著重於柱的圍束及梁抗彎強度,應用在剪力補強方面的研究仍不多。本文嘗試研究碳纖維貼片補強混凝土梁承受剪力作用之行為。其主要目的在探討混凝土梁在低剪力筋量下,使用不同補強方式補強之功效。經過試驗後,知道適當的補強碳纖維貼片對於梁剪力容量的提升幫助很大。此外,並簡介多種國內外已發展的剪力強度公式,提供業界使用碳纖維貼片在剪力補強時提供參考。最後,將剪力補強試驗後所得到的值與Chen和Teng建議之公式計算值作比較,發現Chen和Teng建議之公式在此系列的試驗中具有安全和保守的特性。

並列摘要


Nowadays, use of fiber reinforced plastics (FRP) is one of the common method to amend reinforce concrete structures,because fiber reinforced plastic (FRP) possess the advantages of high strength, light weight, high corrosive ,resistance, and easy working , etc. However, the quality of FRP is checked by traditional tapping on the surface or by a simple pulling test. The tapping method relies very much on the person who carries out the test, so it is inevitable that some defaults may be missed. This paper investigates a new method to check out the defaults in FRP by using infrared photography technology. Experiment results show that infrared photography is a quick and reliable method. Currently, FRP researches usually focus on the confine strength of column and the flexure moment of the beam, and little investigation is carried out on the use of FRP on shear strength of a concrete beam. This paper also studies the effect on shear strength using concrete beams with the same reinforcement but different ways of laying the fiber sheet. Through experimentation, it can comprehend that the shear strength of concrete beam with the fiber sheet can be increase . The test result can be used to strengthen the design methods commonly used in the construction industry.At last, the result of the experimentation is compared with the values from the design proposal given by Chen and Teng, it is found that the design proposal given by Chen and Teng is on safe and conservative side.

參考文獻


1.ACI Committee 318, "Building Code Requirements for Reinforced Concrete," ACI318-95, Detroit, America Concrete Institute.
5.李有豐等人,”FRF複合材料補強橋墩設計準則之研究”,委託單位:交通部科技顧問室。軌行單仕:財團法人臺灣營建研究院,民國88年10月。
6.Al-Sulaimani, G. J. ,and A. Shariff, and I.A. Badunbul (1994),"Shear Repair for Reinforced Concrete by Fiber glass Plate Bonding, "Structural Journal, ACI.,90-100.
8.Chajes, M.J. Thomson , Jr., T.A., and Fraschman, C.A.(1995) "Durability of concrete Beams Externally Reinforced with Composites Fabrics ", Construction and Building Materials,Vol.114,No.3,141-148.
12.Hiroshi F., Gustavo T., and Antonio N.’ Japanese design and construction guidelines for seismic retrofit of building structures with FRP composites’ JBDPA.pp107-118.

被引用紀錄


薛志豪(2009)。RC梁採碳纖維包覆暨化學錨栓補強研究〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://doi.org/10.6841/NTUT.2009.00045
陳韋達(2005)。碳纖維貼片(CFRP)補強鋼筋混凝土矩形梁剪力強度試驗研究〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://doi.org/10.6841/NTUT.2005.00063
賴俐廷(2011)。中空水泥板添加廢棄纖維的改質研究〔碩士論文,中原大學〕。華藝線上圖書館。https://doi.org/10.6840/cycu201100891
王人鋒(2004)。紅外線熱像儀應用於FRP補強 施工品質控制參數最佳化之研究〔碩士論文,中原大學〕。華藝線上圖書館。https://doi.org/10.6840/cycu200400375
宋中仁(2005)。應用EPOXY黏結劑圍束CFRP混凝土定載下高溫性能之研究〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0006-2406200519464500

延伸閱讀