透過您的圖書館登入
IP:18.224.0.25
  • 期刊

應用心跳率控制指標於划船測功儀信效度之分析

Validity and Reliability of Heart Rate Control Index Applied on Rowing Ergometer

摘要


Purpose: to evaluate the validity and reliability of heart rate control (HRC) at 80%, 65%, 50% age-predicted HRmax and intensity variance index (IV(subscript HRC)) index, as well as optimal predictive model on rowing ergometer. Methods: Sixteen rowers (7 males and 9 females, 18.9±2.08 yrs, height: 167.7±7.83cm, weight: 63.1±8.16kg) were recruited to participate in an incremental test (VO2max and W(subscript peak) obtained), and a 2000m performance test (2000max). In addition, 2 trials of 2000m rowing at 80%, 65%, 50% HRmax at least 24hrs apart were also performed, and time to 500m, 1000m, 1500m and 2000m were recorded to obtain HRC index. Results: Intraclass correlation coefficient (ICC) analysis showed that HRC and IV(subscript HRC) at different intensity of HRmax have high test-retest reliability (ICC=0.89~0.99, p<.05), and there was no significant difference between 2 HRC trials. HRC at different intensities of HRmax in 2000m rowing trials showed significant correlation with 2000max (r=.81~.90, p<.05), VO2max (r=-.76~-.85, p<.05) and W(subscript peak) (r=-.80~-.85, p<.05). Moreover, IV(subscript HRC) at different intensities of HRmax were also correlated with 2000max (r=-.82~-.87, p<0.05), VO2max (r=.72~.81, p<.05) and Wpeak (r=.80~.84, p<.05); All of which showed both HRC and IVHRC have good concurrent validity. Simple linear and stepwise regression analysis indicated that HRC and IVHRC also have high predictive validity (R^2=0.63~0.89, p<.05) in 2000max assessment. Conclusion: HRC and IVHRC indices were valid and reliable in applying on rowing exercise, which can be applied in monitoring exercise intensity and predicting performance on rowing exercise.

並列摘要


Purpose: to evaluate the validity and reliability of heart rate control (HRC) at 80%, 65%, 50% age-predicted HRmax and intensity variance index (IV(subscript HRC)) index, as well as optimal predictive model on rowing ergometer. Methods: Sixteen rowers (7 males and 9 females, 18.9±2.08 yrs, height: 167.7±7.83cm, weight: 63.1±8.16kg) were recruited to participate in an incremental test (VO2max and W(subscript peak) obtained), and a 2000m performance test (2000max). In addition, 2 trials of 2000m rowing at 80%, 65%, 50% HRmax at least 24hrs apart were also performed, and time to 500m, 1000m, 1500m and 2000m were recorded to obtain HRC index. Results: Intraclass correlation coefficient (ICC) analysis showed that HRC and IV(subscript HRC) at different intensity of HRmax have high test-retest reliability (ICC=0.89~0.99, p<.05), and there was no significant difference between 2 HRC trials. HRC at different intensities of HRmax in 2000m rowing trials showed significant correlation with 2000max (r=.81~.90, p<.05), VO2max (r=-.76~-.85, p<.05) and W(subscript peak) (r=-.80~-.85, p<.05). Moreover, IV(subscript HRC) at different intensities of HRmax were also correlated with 2000max (r=-.82~-.87, p<0.05), VO2max (r=.72~.81, p<.05) and Wpeak (r=.80~.84, p<.05); All of which showed both HRC and IVHRC have good concurrent validity. Simple linear and stepwise regression analysis indicated that HRC and IVHRC also have high predictive validity (R^2=0.63~0.89, p<.05) in 2000max assessment. Conclusion: HRC and IVHRC indices were valid and reliable in applying on rowing exercise, which can be applied in monitoring exercise intensity and predicting performance on rowing exercise.

參考文獻


王順正、林必寧、王予仕、余奕德、黃彥鈞、程文欣()。
王順正、林正常()。
運動生理學網站網址
林必寧(2006)。不同運動強度與運動時間對跑步機固定心跳率跑速變異的影響(碩士論文)。國立中正大學。
林信甫(2006)。划船選手臨界負荷無氧動力及能量消耗指標與運動表現之相關研究(博士論文)。國立臺灣師範大學。

被引用紀錄


高從耀(2012)。心跳率控制訓練對老年人心肺適能之影響〔碩士論文,國立中正大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0033-2110201613521546
郭泰延(2014)。優秀青少年輕艇選手上下肢慣用側肌力與心肺功能之相關性研究〔碩士論文,國立中正大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0033-2110201613584524

延伸閱讀