透過您的圖書館登入
IP:3.134.87.95
  • 期刊
  • OpenAccess

以矽制可分離球栓塞術治療外傷性頸動脈-海綿竇瘻管-病例報告

Silicone Detachable Balloon Embolization in the Treatment of Traumatic Carotid-Cavernous Sinus Fistula-Case Report

摘要


一位41歲女性病人,因車禍引起複視,右眼球突出併自覺性離音。頭部電腦斷層攝影發現有明顯的右上眼靜脈擴張和併眼外肌肥大。經動脈超音波顯示有內經動脈異常高血流量。腦血管攝影證存在著右內經動脈海綿竇瘺管。 應用經動脈之選擇性矽製可分離球栓塞術治療後,病患症狀得以改善,併發暫時性動眼神經麻痹,經一年五個月長期追蹤,動眼神經連動恢復正常。

關鍵字

無資料

並列摘要


A 41 year-old female suffered from right eye proptosis with spontaneous, subjective bruit noise after car accident. Orbit CT scan revealed dilated prominent superior ophthalmic vein with extra-ocular muscle hypertrophy, OH. Cerebral angiography confirmed direct communication between internal carotid artery and cavernous sinus. Carotid duplex study showed abnormally high flow in right internal carotid artery wills total occlusion of right external carotid artery. Selective trans-arterial embolization with silicone detachable balloon technique give remarkable satisfactory improvement.

延伸閱讀