In the testing flow of an advanced process, the testing under high and low temperature has been become a necessary issue for testing. Testing under variables of high and low temperature is often confronted with the problem of low yield ratio, which is caused often by poor contact. Through observation of probe marks on the bonding pad, this study suggested that when facing the temperature variable, besides the temperature characteristic curve of the components at the design end, the factors of testing environments, such as testing devices and machine settings, are main causes affecting the yield ratio of testing. After observing the deformation of components and comparison of effects caused by various factors, which result in a low yield ratio, this study proposed a better solution for some factors and measures to overcome the effects of environmental factors on the yield ratio.