透過您的圖書館登入
IP:18.118.200.86
  • 學位論文

顯示器色彩之視覺疲勞研究

The Study of Visual Fatigue of Display Color

指導教授 : 歐陽盟
若您是本文的作者,可授權文章由華藝線上圖書館中協助推廣。

摘要


顯示器色彩形成方法基本上分成三類:分時形成法(Time Sharing Method)、空間組成法(Spatial Formation Method)、重疊合成法(Overlay Formation Method),因為色彩形成原理不同,使得人眼觀看顯示器有不同程度之視覺疲勞產生。目前已知分時形成法會產生色分裂(Color Break-Up),容易使人眼疲勞度增加,但評估色分裂對於人眼視覺疲勞影響大小,大多採用主觀評量問卷,因此結果較不客觀。為了提升結果的可靠性及同時比較三種色彩形成法對於視覺疲勞之關係,在此我們利用視調節微動之高頻成分頻譜功率(spectral power of High frequency component of accommodative microfluctuations)作視覺疲勞分析。 研究中利用色輪轉速為1.5及2倍速之單片式DLP投影機(分時形成法)、三片式前投影LCD投影機(重疊合成法)及LCD TV(空間組成法,以CCFL為背光源之電視)當做色彩形成法研究之對象。實驗分別以靜態及動態模式於同一視距、不同觀看時間進行人眼刺激,在觀看顯示器前後均利用睫狀體調節微動分析儀紀錄受測者視調節微動情形,其中在動態實驗又加入主觀評量問卷分析實驗結果。 實驗結論分成靜態及動態兩部份: (一) 靜態實驗中,LCD TV給予人眼負擔比1.5x-DLP及三片式LCD投 影機小,但是與2x-DLP無顯著之差異存在。 (二) 動態實驗中,經由主客觀交叉比對後得到1.5x-DLP給予人眼負擔 高於2x-DLP及三片式LCD投影機。 本研究已初步將色彩形成法與視覺疲勞之關係建立出來,未來將改變實驗中之參數,希望更清楚地闡明兩者之關係。

並列摘要


The color formation methods of the display basically divide into three kinds of methods: Time sharing method, Spatial formation method and Overlay formation method. Since color formation principles are different, they make the human eyes have differently visual fatigue. So far Time sharing will produce color break-up, and it’s easy to make human eyes be tired degree increase. It mostly uses subjective questionnaire method to assess visual fatigue from color break-up, so the results are less objective. In order to improve dependability and compare three color formation methods to the visual fatigue at the same time, we analyse visual fatigue by spectral power of high frequency component of accommodative microfluctuations. In this study, we use 1.5x and 2x speed of color wheel single-chip DLP projector (time sharing method), a three-panel LCD projector (overlay formation method) and a LCD TV (spatial formation method) to investigate the color formation methods. The experiment divides into two modes: static and dynamic mode, and they stimulate human eyes at the same visual distance, different viewing time. Before and after viewing the displays, it must use auto refract-keratometer to record accommodative microfluctuations of subjects. In addition, we increase subjective questionnaire method to assess visual fatigue in the dynamic mode. The experiment conclusions are divided into two parts of the static and the dynamic mode: (a) In the static experiment, the LCD TV has slighter visual fatigue than the 1.5x-DLP projector and the three-panel LCD projector, but it does not have apparent difference to the 2x-DLP projector. (b) In the dynamic experiment, the 1.5x-DLP projector has more serious visual fatigue than the 2x-DLP projector and the three-panel LCD projector via subjective and objective method. In this research we have already found the relation between color formation methods and visual fatigue, and will change the parameters in the experiment in the future. We hope to expound the relation between them more clearly.

參考文獻


[40]馮文陽, "照明因子對視覺績效與視覺疲勞之影響," 中原大學工
microfluctuations and pupil size during sustained viewing of
visual display terminals," Ophthalmic and Physiological Optics, vol.
microfluctuation in asthenopia caused by accommodative spasm,"
Fukushima J Med Sci, vol. 47, no. 1, pp. 13-20, 2001.

被引用紀錄


鄧經緯(2013)。平板電腦螢幕色彩組合在全暗空間中對視認性與視覺疲勞之關聯〔碩士論文,國立臺北科技大學〕。華藝線上圖書館。https://doi.org/10.6841/NTUT.2013.00543
黃冠涵(2017)。使用虛擬實境眼鏡對於視覺敏銳度、認知記憶力以及疲勞、舒適程度的影響〔碩士論文,國立臺灣大學〕。華藝線上圖書館。https://doi.org/10.6342/NTU201704355
羅羽辰(2010)。視距與顯示器型態對視覺績效與疲勞之影響〔碩士論文,朝陽科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0078-0601201112113308
彭家偉(2011)。面板技術與刺激型態對視覺疲勞出現時間之影響〔碩士論文,朝陽科技大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0078-1511201110382725
夏繼源(2011)。睫狀肌微波動與LED眩光之研究〔碩士論文,國立中央大學〕。華藝線上圖書館。https://www.airitilibrary.com/Article/Detail?DocID=U0031-1903201314414807

延伸閱讀