透過您的圖書館登入
IP:3.21.76.0
  • 期刊

登階運動後不同恢復期心跳數與心肺耐力指數評估最大攝氧量之分析

Estimation of VO2max: A Comparative Analysis of Postexercise Heart Rate and Cardiorespiratory Endurance Endex from 3-minute Step Test

摘要


The purpose of this study was to evaluate the accuracy of three postexercise heart rate parameters from 3-min step test to estimate VO2max. Thirty-one college male subjects (M±SD=19.77±1.20 years; 173.31±6.62 cm; 64.34±8.91 kg) had VO2max (M±SD=47.08±3.39 ml•kg^(-1)•Min^(-1)) measured by Bruce treadmill test. Subjects performed three step tests (24 ascents/min) with stepping height were 30, 35, and 40 cm, respectively. Direct measurements of VO2max obtained from the treadmill test were correlated with 5 to 20-sec postexercise heart rate (PHR15), 60-sec postexercise heart rate (PHR60), and Cardiorespiratory Endurance Index (CEI) calculated after three different step test protocols. Linear regression analysis used to determine the estimate VO2max deviated from the measured VO2max. An alpha level of .05 was selected. Results indicated the CEI from performing 3-min step test with 40 cm of stepping height and 24 ascents/min of stepping cadences was seemed to be a more effective (r=.50) and lower standard error of estimates (SEE=2.94 ml•kg^(-1)•Min^(-1)), which was practical field test to estimate the aerobic fitness of college males.

並列摘要


The purpose of this study was to evaluate the accuracy of three postexercise heart rate parameters from 3-min step test to estimate VO2max. Thirty-one college male subjects (M±SD=19.77±1.20 years; 173.31±6.62 cm; 64.34±8.91 kg) had VO2max (M±SD=47.08±3.39 ml•kg^(-1)•Min^(-1)) measured by Bruce treadmill test. Subjects performed three step tests (24 ascents/min) with stepping height were 30, 35, and 40 cm, respectively. Direct measurements of VO2max obtained from the treadmill test were correlated with 5 to 20-sec postexercise heart rate (PHR15), 60-sec postexercise heart rate (PHR60), and Cardiorespiratory Endurance Index (CEI) calculated after three different step test protocols. Linear regression analysis used to determine the estimate VO2max deviated from the measured VO2max. An alpha level of .05 was selected. Results indicated the CEI from performing 3-min step test with 40 cm of stepping height and 24 ascents/min of stepping cadences was seemed to be a more effective (r=.50) and lower standard error of estimates (SEE=2.94 ml•kg^(-1)•Min^(-1)), which was practical field test to estimate the aerobic fitness of college males.

參考文獻


王文筆、林正常(2002)。登階測驗恢復方式對心肺耐力指數的影響-以政治作戰學校專科二年級男生為例。大專體育學刊。4(2),179-186。
王順正、林正常(1995)。登階測驗評估最大攝氧量的效度概化。體育學報。20,351-362。
吳忠勳(2004)。遞增運動負荷登階測驗和800公尺跑走與最大攝氧量之相關研究(碩士論文)。國立屏東師範學院。
林正常(1995)。運動生理學實驗指引。臺北市:師大書苑有限公司。
行政院體育委員會(1998)。國民體能檢測實務手冊。臺北市:行政院體育委員會。

被引用紀錄


傅思凱、林靜茹、賴長琦、王怡品、余家賢(2022)。漸增式間歇訓練對空手道對打項目選手健康體適能之影響淡江體育學刊(25),46-55。https://doi.org/10.6976/TJPE.202211_(25).0004
李少騰(2012)。不同程度肥胖童之心肺適能與身體活動量關係之研究〔碩士論文,國立屏東科技大學〕。華藝線上圖書館。https://doi.org/10.6346/NPUST.2012.00028

延伸閱讀